Repeaters
Programming the CS100 Repeater
We recommend you use the following instructions for programming the
repeater.
Identify the preferred location for the repeater by measuring the
received signal strength walking away from the base station using the
feature code*99981*. The display will show RPN:xx which is the base
station,Q52:64 which is the radio data and RSSI:xx which is the signal
strength.
We recommend that a call is set up between two handsets and
that one person walks away from the base station observing the display
and continuing a conversation. Move to the location where the repeater is
required checking that the Q52 reading remains at 64 and that the speech
quality remains good. If at any time either of these factors change, you
have reached the maximum recommended distance from the base station
to where the repeater may be located.
Repeat this process for any additional repeaters, ensuring that the test
handset is using the base station or the repeater for its communications.
This is critical if repeaters are to be placed in a chain as the signal
measurement and speech quality MUST be checked from the repeater.
Section 5.3 provides detail instructions.
Handset feature codes
*99981* OK Signal strength
*99982* OK Software version
*99985* OK Battery status
*99989* OK 4 Channel coverage test