9261-8173 issue: 8 Page 24
© 2012 Multitone Electronics Plc
Interface connections
Plug in the AC to DC power adapter provided with the hub.
Plug in the Ethernet patch lead to connect to the LAN or PC. See ‘Connecting
the hub to the PC using Windows XP (page 41).
If an external alarm is to be activated from the hub, connect a pair of wires from
the alarm output shown in the interface connections diagram. The alarm output
is a simple make/break contact and can be used to operate a customer
provided alarm relay. This is not designed to provide a direct contact for AC
mains operated equipment.
Connect the DB9 port A connections to the customer's paging system if
required. The connection cable should be as specified by the paging system.
A PPP connection can be made after the modem has been set up via port B.
See ‘Installing the PPP modem’ (page 31) for further details.
3. Installing the repeater, mains powered repeater and call
point
Mounting the repeater or call point (incl. mains powered variants)
Remove the back plate from the device by removing screw A and sliding the
top and the base in opposite directions as shown by the green arrows. The
standard repeater is shown in the diagram; the call point and mains powered
devices are opened in the same way.
Port A -
(DB9)
Port B -
(DB9)