User's Manual

RPT 633
Page 4 - 4 TM1184 Issue 1
7. When connecting an RPT 633 transmitter to a Access 3000, it is first necessary to
use Engineering Mode Test 50 to configure the Encoder into the Non-DTMF mode.
The connections shown in Table 1 and 2, as applicable, should then be made
between the encoder and transmitter.
Table 1: Encoder Mounted in a Card Frame Assembly
SIGNAL ENCODER D TYPE CABLE COLOUR *TRANSMITTER
NAME PIN No. PIN No. TYPE CODE INPUT
Data 29c 9 } 0401-0009 { Orange } SKT2 {left
0V 30a 23 } { White/Blue } {right
Speech { 12a 17 } 0401-0011 { Violet } SKT1 {right
{ 12c 4 } { Yellow } {left
* As seen from the rear of the transmitter.
Table 2: Encoder mounted in a Single Slot Housing
SIGNAL ENCODER CABLE COLOUR *TRANSMITTER
NAME PIN No. TYPE CODE INPUT
MODULAR
JACK
PIN No.
Data 29c 7 } 0301-0092 { Yellow } SKT2 {left
0V 30a 6 } { Blue } {right
Speech { 12a 2 } 0301-0091 { Orange } SKT1 {right
{ 12c 4 } { Red } {left
* As seen from the rear of the transmitter.
8. Power Supply
Ensure that the power supply is correctly rated for your application and has the
correct mains connector. Insert the power supply outlet plug into SK3 at the rear
of the unit and plug the supply into the mains socket.