installation Operation mechanism and working range 1 Names and functions of parts 2 Safety cautions 3 Remote control operation procedure 5 Optimum operation 14 Trouble shooting 15 Installation notes 17 Care and maintenance 18 Technical specifications 23 Installation accessories and drawings 24 Indoor unit installation 26 Outdoor unit installation 36 Test and check items after installation 38 Thank you purchasing this MUNDOCLIMA air conditioner.
Operation mechanism and working range. Working temperature range. Indoor side DB/WB ( ) Outdoor side DB/WB ( ) maximum cooling 32/23 43/26 minimum cooling 21/15 21/15 maximum heating 27/- 24/18 minimum heating 20/- -5/-6 Schematic diagram of refrigeration Operation mechanism and working range 1. Schematic diagram of cooling type 1 2. Schematic diagram of heat pump type 1. Indoor heat-exchanger 2. Connecting pipe 3. Check valve 4. Accumulator 5. Compressor 6. Filter 7.
Names and functions of parts.
Safety cautions Read the following instructions carefully before use. Safety cautions Warning 3 Avoid direct air flow to your body and avoid excessive heating or cooling,which may make you feel uncomfortable and do harm to your health. Check whether the installed stand is still firm enough after the unit has operated for a long time. If a worn-out stand is left unfixed,the unit may topple and do harm. Do not remove protection grill nets from the outdoor unit.
Safety cautions Warning Do not check or repair during the unit is operating. It is very dangerous. Do not use other heating equipment near the air conditioner. It will affect the cooling performance. Safety cautions Never place objects near the air intake and the air outlet of the unit. It may affect performance or stop operation of the unit. Do not splash water directly to indoor unit It may cause trouble or electric shock. Do not bang the remote controller.
Remote control operation procedure Name and Function-Remote control Note: Be sure that there are no obstructions. Don’t drop or throw the remote controller. Don’t place the remote controller directly in the sunlight. SWING button Remote control operation procedure When it is pressed, the louvers start to rotate automatically and stop when repressed. TEMP.button SET TEMP. increases 1 by pressing button once,and decreases 1 by pressing button once. At COOL mode operation, SET TEMP.
Remote control operation procedure Name and Function-Remote control. (Remove the cover) Note: This type of remote controller is a kind of new current controller. some buttons of the controller which are not available to this Air conditioner will not be described below. SLEEP button Press this button to set SLEEP operation. Remote control operation procedure Liquid crystal displayer. It shows all set contents.
Remote control operation procedure COOL mode operation procedure According to difference between room temp. and set temp., microcomputer can control cooling on or not. If room temp. is higher than set temp., compressor runs at COOL mode. If room temp. is lower than set temp., compressor stops and only indoor fan motor runs. Set TEMP. should be in range of 16 to 30 Remote control operation procedure 4.Press FAN button, set fan speed. 3.
Remote control operation procedure HEAT mode operation procedure If room temp. is lower than set temp., compressor runs at HEAT mode; If room temp. is higher than set temp., compressor and outdoor fan mortor stop, only indoor to 30 3.Press SWING button, the louvers start to rotate automatically, and stop when repress it. 4.Press FAN button, set fan speed. 5.Press TEMP. button, set suitable TEMP. Remote control operation procedure fan mortor runs. Set TEMP. should be in range of 16 1.
Remote control operation procedure DRY mode operation procedure If room temp. is lower than set temp., compressor ,outdoor and indoor fan mortor stop. If 2 of set temp., Air conditioner is drying.If room temp. is higher room temp. is between Remote control operation procedure than set temp., it’s at COOL mode. Set TEMP. should be in range of 16 to 30 3.Press SWING button, the louvers start to rotate automatically, and stop when repress it. 4.Press TEMP.button,set suitable TEMP. 2.
Remote control operation procedure AUTO mode operation procedure for COOL mode and 20 for HEAT Remote control operation procedure At AUTO mode operation, standard TEMP. is 25 mode. 1.Plug in,Press 1/0 button, then air conditioner is turned on. 2.According to room temp.,microcomputer can automatically set operation mode,so as for best effect.
Remote control operation procedure Remote control operation procedure TIMER mode operation procedure At stopping,press TIMER ON button, set ON TIME in range of 0 to 24 hour to start the unit automatically. At operating,press TIMER OFF button.set OFF TIME in range of 0 to 24 hour to stop the unit automatically.
Remote control operation procedure SLEEP mode operation procedure When the unit is cooling or drying, if SLEEP operation is set, TEMP. would increase 1 hour and 2 in 2 hour. Indoor fan motor runs at low speed. When the unit is heating , if SLEEP operation is set, TEMP. would decrease 1 2 in 2 hours. Indoor fan motor runs at low speed. in 1 in 1 hour and 4.Press FAN button, set fan speed. Remote control operation procedure 3.
Remote control operation procedure How to insert batteries Remote control operation procedure 1. Remove the cover from the back of the remote controller. 2. Insert the two batteries ( Two AAA dry - cell batteries ) and press button “ACL”. 3. Re - attach the cover. Note: Don’t confuse the new and worn or different types of batteries. Remove batteries when the remote controller is not in use for a longtime. 2 Insert the 7# batteries. 1 Remove the cover. 3 Re - attach the cover.
Optimum operation Adjust the room temperature properly Adjust the room temperature properly for a comfortable environment. Never place anything under the indoor unit that is to be kept dry. Water may drop from the indoor unit when the humidity is over 80% or when the drainage outlet is clogged. When the main power switch is truned on, some watts of electricity is being used even if the system is not operating. Turn off the main power supply switch to save energy.
Trouble shooting Warning * In case of something abnormal (such as bad smell), shut off the power switch immediately and contact service center. * Do not repare the air conditioner by yourself. Because wrong repair may cause fire, please contact service center. Check these items shown below before contacting service center.
Trouble shooting The following are not troubles “Trouble” Cause The unit does not Restart right after stopping Once the unit is stopped, it will not operate operate when Press SET TEMP. and then release immediately. for about 3 minutes to protect it Power is switched on Wati for 1 minute When cooling Room air is chilled rapidly and becomes Mist is emitted foggy. Outdoor unit is hot after the unit is stopped Compressor is emitting heat to get ready for restarting.
Installation notes Location The air conditioner must be firmly installed and 3 4 liability checks must be done every year. Avoid place whthin easy reach of young children. Avoid other heat sources or dircect sun light. Install indoor unit away from TV set or radio. Avoid where inflammable gas is likely to leak. At salty coastal areas or special areas such as the vicinity of a sulphurous hot spring,please contact dealer before installation to make sure it is safe to use the unit.
Care and maintenance Please pull out the power plug after you used the air conditioner. Warning Pull out the power plug before cleaning Do not splash water directly to the unit How to clean the air filter 1.Open the suction grille Use screwdriver screws the two screws. Slide both knobs simultaneously as shown and 2.Remove the air filters. Slide knobs on the back of the suction grille outward and remove the air filter. Then romove three air cleaners on it.
Care and maintenance 4.Fix the air filters Replace the air filter into its holder. Make sure that the air filter makes contact with the filter stopper when it is replaced into its holder. Care and maintenance Shut the suction grille. Refer to step 1. How to clean the suction grille 1.Open the suection grille. See step 1 of “How to clean the air filter” 2.Remove the air filters. See step 2 of “How to clean the air filter” 3.Remove the suction grille Open the suction grille at 45 and then lift. 4.
Care and maintenance Before starting the air conditioner for the first time in the season 1.Check to make sure no objects obstructing the intake and outlets parts on both the indoor and outdoor units. 2.Check to make sure ground wire is connected and that it is not damaged. 3.Check to make sure air filter has been cleaned. 4.Turn on the power 6 hours before starting the air conditioner. End of seaseon cleaning 3.Clear outdoor unit of dust. 4.
Care and maintenance Power supply and wiring requirement 1. Power frequency of air-conditioner should be 60Hz, voltage: AC 230V±10% If voltage are over may cause the parts of electric equipment damaged. If the voltage are too low may cause shake on compressor, it may let the cooling system damaged, and also, the compressor and parts will not work. Voltage should be stable, which cannot have a big fluctuation. 2. User power supply should be provided a reliable earthing connect. (see earth requirement) 3.
Care and maintenance Caution 1. Please check the earth connection before running test. 2. Voltage should be following the requirement. The voltage should not be too big after the running test (normally, 9000BTU unit not over 15V, 18000BTU unit not over 10V, 28000BTU unit not over 5V. 3. Electric meter should have enough current, watt capacity. Other requirement 1. Installation of air conditioner must be far away from combustibles, for instance, window curtains and cloths.
Technical specifications Technical specifications Model MUCS-18 C MUCS-18 H Functions Cooling Cooling/heating Cooling capacity W 5000 5000 Heating capacity W — 5500 Rated voltage and frequency Cooling/Heating Input current A 10 / — 10 / 9.5 Maximum Current input A 15 15 2.8 / — 2.8 / 2.4 680 680 R 407 C 1.95 R 407 C 1.
Installation accessories Accessories No. Name 1 Shape Quantity Notes Drainage hose 1 For indoor side pipe joint 2 Clamp 1 For hole 3 Nylon fastener 4 L=200 4 Washer 10 10 5 Paper pad for installaition 1 6 Screws 4 7 Heat preservation Sponge for pipe 2 8 Big sealing pad 1 5 160 300 9 Sealing pad 1 5 45 300 10 Small sealing pad 2 3 30 150 11 Sealing bar 1 120 12 PVC tape 2 30 13 Screws 8 ST4.
Installation accessories and drawings Installation drawings Installation accessories and drawings Indoor unit Outdoor unit Note: Air conditioner must be installed by skilled personnel according to this manual.
Indoor unit installation Location 1.Do not place object near the air oulet so that conditioned air can reach the whole room. 2.Be sure to install the indoor unit firmly and horizontly. 3.Select the place that can support 4 times of the indoor unit’s weight and will not increase noise and vibration. 4.Select a place easy to drain water and connect with the outdoor unit. 5.Make sure there is enough space for maintenance and make sure the distance between the unit and ground is 1.8m or more. 6.
Indoor unit installation Fig.5 Hanging preparations Indoor unit installation (1) Install special nut A, then special nut B onto the hanging bolt. (Fig.6) (2) Raise the body and mount its hooks onto the hanging bolt between the special nuts. (Fig.6) (3) Turn special nut B to adjust the height of the body. (Fig.6) (4) Leveling a level, or vinyl hose filled with water, fine adjust so that the body is level. Warning Perform final tightening by tightening the double nut firmly. Fig.
Indoor unit installation Fig.7 NOTE: Install the drain pipe. Install be drain pipe with downward gradient (1/50 to 1/100) and so there are no rises or traps in the pipe. Use general hard polyvinyl chloride pipe (VP25) [outside diameter 1-1/4” (32mm)] and connect it with adhesive (polyvinyl chloride) so that there is no leakage. When the pipe is long, install supporters. Always heat insulate the indoor side of the drain pipe.
Indoor unit installation Connecting the pipes Besure to use both a spanner and wrench together as shown in the drawing during connecting or disconnecting pipes to/from the unit. The pipe of water-in/out is pipe thread G3/4.The surface of thread should be enlaced by the two or three-circles trap. After the water-in pipe and water-out pipe is connecting tightly,starting the water pump,then checking it’s airproof performance. Insulate it as shown in the drawing below.
Indoor unit installation Electrical wiring How to connect wiring to the terminals A. For solid core wiring (or F-cable) (1) Cut the wire end with a wire cutter or wire-cutting pkiers, then stuip the insulation to about 15/16” (25mm) of expose thn solid wire. (2) Using a screwdriver,remove the terminal screw (s) on the terminal board. (3) Using pliers, bend the solid wire to form a loop suitable for the terminal screw.
Indoor unit installation Indoor unit side Remove the control box cover and install the connection cord. (Fig. 12 and 13) Fig.12 Control box cover Indoor unit installation Fig.
Indoor unit installation Bolting the grille assembly to the body Install the grille assembly to the body with the four bolts,spring washers,and washers. Fig.16 Washer Spring washer No gap between ceiling and grille around entire periphery. Wireless unit connection wire wiring (1). Connect the connector in accorbance part A detail view. (2). Then clamp the lead wire with clamp so that it does not touch the rotating parts. Indoor unit installation Bolt Fig.
Indoor unit installation Fig.18 Part A detail view Installing/Removing the intake grille 1. Installing the intake grille Indoor unit installation (1) Full insert the intake grille hooks into the rectangular holes in the panel. Fig.19 (2) Close the intake grille,then slide the tow grille stoppers outward. Fig.
Indoor unit installation 2.Removing the intake grille (1) Slide the two grille stoppers inward,and then open the iotake grill. Fig.21 Grille stopper (2) Remove the geille hook screws, and then open the intake grille. Grille hook Indoor unit installation Fig.22 (3) Open the intake grille so that it is at an angle of 20° to 40° ,and then remove the grille. Fig.23 Caution: (1)the louver angle cannot be changed if the power is not no, (It moved by hand,ir may be damaged.
Indoor unit installation Connection of refrigerant pipe Besure to use both a spanner and torque wrench together as shown in the drawing,connecting or disconnecting pipes to/from the unit. Refer to table 1 to determine the proper tightening torque (over tightening may damage the flare and cause leaks.) When conecting the flare nut,coat the flare both inside and outside with refrigerating machine oil and initially tighten by hand 3 or 4 turns.
Outdoor unit installation Selecting installation site Select an installation site where the folliwing conditions are satisfied and that meets with your customer’s approval. Places which are well-ventilated. Safe places which can withstand the unit’s weight and vibration and where the unit can be installed level. Places where the unit does not bother next-door neighbors. Places where there is no possibility of flammable gas leak.
Outdoor unit installation Electric wiring (1) Read the name plate carefully,then arrange wiring according to the “WIRING DIAGRAM”. (2) A circuit breaker capable of shutting down power supply to the entire system must be installed. (3) Earth properly. (4) All wiring must be perfomed by a skilled electrican according to the “WIRING DIAGRAM”. Wrong wiring may cause fire of electric shock. Connect the power connecting wires (1) Remove the front side plate (Fig.
Test and check item after installation 1. Prepare for test (1) Do not turn on the power switch before all installation is finsihed. (2) Connect wires corectly and firmly. (3) Open the check valve. (4) Remove all dust. 2. Testing (1) Turn on the power switch and press “1/0” button. (2) Press “MODE” button select COOL,HEAT,FAN,etc to test whether it operates mormally. 3.Emergency operation. When the batteries fail or when the remote controller is missing,operate as shown below.