User`s manual
M180-MLT350 Dehumidifiers
26
6 Product Design Information 190TGB-1034-A
6.3 Dimensions and service space
Scaled and dimensioned AutoCAD drawings are available in Munters’
DryCAD program (can be ordered at the nearest Munters office).
Figure 6-2. Dimensions & service space
Model
Dimensions Weight
(kg)
ABCØDØEFGHJLMNPX
1
Y
1
ML180 513 410 910 125 80 220 170 500 135 170 250 45 175 450 400 56
MLT350 513 410 910 125 80 220 170 500 135 170 250 45 175 450 400 56
ML270 513 410 1010 160 100 220 170 600 135 170 250 450 175 450 400 63
1
Access space required for servicing
Table 6-1. Dimensions and service space
s
420
ML
Munter
145
110
249
165
145
110
B
J
Y
C
P
M
L
1
2
ØD
N
X
A
N
4
ØE
3
F
H
G
P
1. Process air inlet
2. Dry air outlet
3. Reactivation air inlet
4. Wet air outlet
Service space
area