User's Manual

Configuring the Network
Status Commands
These commands deal with general interface aspects of the operation of the HopNet.
Command
Description
zb[?|0|1]
Banner Display Disable
0 = disabled
1 = enabled (default)
zh?
Read factory serial number high byte.
zm?
Read factory serial number middle byte.
zl?
Read factory serial number low byte.
z>
Exit Modem Control Mode
z!
Software Reset
do[?|0|1]
DTR Operational
0 = does not obey DTR
1 = does obey DTR
2 = reads status
Banner Display Disable
Enables or disables display of the banner string and revision code automatically at
power-up. May be disabled to avoid being mistaken for data by the host.
Read Factory Serial Number High, Middle and Low Bytes.
These read only commands return one of the three bytes of the unique factory-set
serial number, which are also visible in the startup banner.
DTR Operation
Sets whether or not the radio obeys DTR .
HopNet 110 17