Datasheet

NDL Series
Isolated 2W Wide Input Single Output DC/DC Converters
KDC_NDL.F05 Page 1 of 4
www.murata-ps.com
www.murata-ps.com/support
For full details go to
www.murata-ps.com/rohs
 
SELECTION GUIDE
Order Code
Input
Voltage
Rated Output
Voltage
Output Current
1
Input Current
2
Efficiency
Isolation
Capacitance
MTTF
4
Min Load
3
Full Load Full Load
V (nom.) V mA mA mA % pF kHrs
NDL0505SC
5 5 100 400 606 66 26 2015
NDL0509SC
5 9 55 222 558 71 27 1998
NDL0512SC
5 12 42 167 559 71 26 1980
NDL0515SC
5 15 33 134 549 73 27 1965
NDL1205SC
12 5 100 400 228 73 39 1994
NDL1209SC
12 9 55 222 211 79 38 1981
NDL1212SC
12 12 42 167 208 80 47 1961
NDL1215SC
12 15 33 134 206 81 47 1947
NDL2405SC
24 5 100 400 112 74 37 1722
NDL2409SC
24 9 55 222 102 81 40 1711
NDL2412SC
24 12 42 167 100 83 51 1696
NDL2415SC
24 15 33 134 100 83 58 1685
NDL4805SC
48 5 100 400 57 73 39 1719
NDL4809SC
48 9 55 222 52 80 40 1709
NDL4812SC
48 12 42 167 51 81 53 1694
NDL4815SC
48 15 33 134 51 82 65 1683
INPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Voltage range
All NDL05 types 4.5 5 9
VDC
All NDL12 types 9 12 18
All NDL24 types 18 24 36
All NDL48 types 36 48 72
Reflected ripple
current
All NDL05 types with 100µF at input 250
mA p-p
All NDL12 types with 100µF at input 150
All NDL24 types with 10µF at input 300 380
All NDL48 types with 10µF at input 140 170
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection Continuous
Lead temperature 1.5mm from case for 10 seconds 300°C
Control pin input current 15mA
Input voltage 05 types 10V
Input voltage 12 types 20V
Input voltage 24 types 40V
Input voltage 48 types 80V
1. Refer to power derating graph for operating of 5V input types at 4.5 to 6V.
2. Measured at full load with external input/output capacitors.
3. Please refer to minimum load application notes section on page 3.
4. Calculated using MIL-HDBK-217F with nominal input voltage at full load.
All specifications typical at T
A=25°C, nominal input voltage and rated output current unless otherwise specified.
FEATURES
RoHS compliant
2:1 wide range voltage input
Continuous short circuit protection with
current foldback
Operating temperature range -40ºC to 85ºC
0.75% regulation
1kVDC Isolation
Efficiency to 83%
Power density 0.9W/cm
3
5V, 12V, 24V & 48V nominal input
5V, 9V, 12V & 15V output
No electrolytic capacitors
Fully encapsulated
External control
Low noise
Fully encapsulated
DESCRIPTION
The NDL series is a range of high performance
miniature DC/DC converters having regulated out-
puts over the wide temperature range of -40ºC to
85ºC. The input voltage range is 2:1 with the output
power at 2 watts and the input to output isola-
tion is 1kVDC. Continuous short circuit protection,
external control and extremely small SIP packaging
provide state of the art functionality. Nominal input
voltages of 5, 12, 24 and 48V with output voltages
of 5,9,12 and 15V are available as standard with
custom parts on request. The plastic case is rated
to UL94V-0 with encapsulant to UL94V-1.

Summary of content (4 pages)