Datasheet

NKA Series
Isolated Sub-Miniature 1W Dual Output DC/DC Converters
KDC_NKA.J02 Page 3 of 7
www.murata-ps.com/support
TOLERANCE ENVELOPES
100
75
50
25
10
-7%
+9%
Output Load Current (%)
Output Voltage
+1%
-15%
-7%
+1%
Typical Load Line
V
NOM
3.3V output types.
All other types.
+10%
Output Load Current (%)
Output Voltage
+5%
-7.5%
-2.5%
+2.5%
Typical Load Line
V
NOM
100
75
50
25
10
TEMPERATURE DERATING GRAPHS
150100
50
0
-40
0
0.5
1.0
1.5
Safe Operating Area
85°C
Ambient Temperature (°C)
Output Power (W)
150100
50
0
-40
0
0.5
1.0
1.5
Safe Operating Area
85°C
Ambient Temperature (°C)
Output Power (W)
120°C
NKA0303DC/SC, 0305DC/SC
0309DC/SC, 0505DEC/SEC
types only.
All other types.
The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to
changes in output loading.