Datasheet
NKE Series
Isolated Sub-Miniature 1W Single Output DC/DC Converters
KDC_NKE.K07 Page 3 of 7
www.murata-ps.com/support
TOLERANCE ENVELOPES
3.3V output types.
All other types.
100
75
50
25
10
-7%
+9%
Output Load Current (%)
Output Voltage
+1%
-15%
-7%
+1%
Typical Load Line
V
NOM
+10%
Output Load Current (%)
Output Voltage
+5%
-7.5%
-2.5%
+2.5%
Typical Load Line
V
NOM
100
75
50
25
10
TEMPERATURE DERATING GRAPHS
150100
50
0
-40
0
0.5
1.0
1.5
Safe Operating Area
85°C
Ambient Temperature (°C)
Output Power (W)
150100
50
0
-40
0
0.5
1.0
1.5
Safe Operating Area
85°C
Ambient Temperature (°C)
Output Power (W)
120°C
NKE 0303DC/SC, 0305DC/
SC, 0309DC/SC, 0503DC/SC,
0505DEC/SEC types only.
All other types.
UL recognition to a
maximum ambient
temperature of 85ºC and/
or case temperature limit of
130ºC.
The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to
changes in output loading.