Datasheet

NMXSO Series
Isolated 5W Regulated Single & Dual Output DC/DC Converters
KDC_NMXSO.E01 Page 1 of 3
www.murata-ps.com
www.murata-ps.com/support
For full details go to
www.murata-ps.com/rohs
 
SELECTION GUIDE
Order Code
Nominal Input
Voltage
Output
Voltage
Output Current
Efficiency
Typ.
Isolation
Capacitance
Output Power
MTTF
1
V V A % pF W kHrs
NMXD1215SOC 12 ±15 ±0.2 65 65.7 6.0 61
NMXS0505SOC 5 5 1.0 65 37.4 5.0 811
NMXS1205SOC 12 5 1.0 65 46.6 5.0 177
Obsolete
Recommended
Alternative
NMXD0505SOC 5 ±5 ±0.5 65 30.5 5.0 565 BWR-5/700-D5A-C
NMXD0515SOC 5 ±15 ±0.2 65 36.6 6.0 83 NCS6D1215C
NMXD1205SOC 12 ±5 ±0.5 65 40.5 5.0 162 BWR-5/900-D12A-C
NMXS0515SOC 5 15 0.4 65 33.3 6.0 157 UWR-15/530-D5A-C
NMXS1215SOC 12 15 0.4 65 60.0 6.0 93 UWR-15/665-D12A-C
NMXD0512SOC Obsolete n/a
NMXD1212SOC
Obsolete, recommended alternative: (click for data sheet) NCS6D1212C
NMXS0512SOC Obsolete n/a
NMXS1212SOC
Obsolete, recommended alternative: (click for data sheet) NCS6S1212C
When operated with additional external load capacitance the rise time of the input voltage will determine the maximum external
capacitance value for guaranteed start up. The slower the rise time of the input voltage the greater the maximum value of the
additional external capacitance for reliable start up.
INPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Voltage range
Continuous operation, 5V input types 4.5 5.0 5.5
V
Continuous operation, 12V input types 10.8 12.0 13.2
Reflected ripple voltage BW=DC to 20MHz, all output types 150 mV
OUTPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Rated power TA= 0°C to 70°C 5.0 W
Voltage output accuracy ±3 %
Line regulation High V
IN to low VIN ±0.5 %
Load Regulation 10% load to rated load 0.5 %
Ripple and Noise BW=DC to 20MHz, all output types 150 mV p-p
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection
2
15 seconds
Lead temperature 1.5mm from case for 10 seconds 300°C
Input voltage V
IN, NMXSO05 types 7V
Input voltage V
IN, NMXSO12 types 15V
1. Calculated using MIL-HDBK-217F with nominal input voltage at full load.
2. Supply voltage must be disconnected at the end of the short circuit duration.
All specifications typical at T
A=25°C, nominal input voltage and rated output current unless otherwise specified.
FEATURES
RoHS compliant
Single or dual output
1kVDC isolation
Pin compatible with NMXU series
Power density 0.53W/cm
3
UL 94V-0 package material
Footprint 9.52cm
2
Industry standard pinout
5V & 12V input
5V & 15V output
Short circuit protected
Internal SMD construction
Fully encapsulated with toroidal magnetics
Output regulation 0.5%
PCB mounting
DESCRIPTION
The NMXSO series of DC/DC converters is
particularly suited to isolating and/or converting
DC power rails. The galvanic isolation allows the
device to be configured to provide an isolated
negative rail in systems where only positive rails
exist. The devices are particularly suited for use
in distributed power systems where there is low
variation in the bus voltage levels.
Sin
s
NOT RECOMMENDED
FOR NEW DESIGNS
Isolated 5
Isolated 5
S

Summary of content (3 pages)