Datasheet

PART NUMBER STRUCTURE
PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE
Model Number
Output Input
Effi ciency
Case
Dimensions are
in inches (mm)
VOUT
(Volts)
IOUT
(Amps,
max)
Power
(Watts)
R/N
(mVp-p)
Max. d
Regulation (Max.)
Vin Nom.
(Volts)
Range
(Volts)
e
Iin,
no load
(mA)
Iin,
full load
(Amps)Line Load Min. Typ.
OKX-T/3-D12-C .7525-5.5 3 15 20 ±0.15% ±0.3% 12 8.3-13.8 40 1.344 91.5% 93.0%
0.40x0.90x0.282
(10.16x 22.86x 7.163)
Maximum Rated Output
Current in Amps
Trimmable Output
Voltage Range
D12 Models = 0.7525-5.5V
Input Voltage Range
D12 = 8.3-13.8V
On/Off Logic
P = Positive Logic
N = Negative Logic
-/ D12-T 3
Okami Non-isolated PoL
SIP Mount
XOK C-
RoHS Hazardous Substance Compliance
C = RoHS-6 (does not claim EU RoHS
exemption 7b–lead in solder)
N
Note: Some model number combinations
may not be available. See Ordering Guide
above. Contact Murata Power Solutions for
availability.
All specifications are at nominal line voltage, Vout=nominal (5V for D12 models) and full load, +25°C unless otherwise
noted.
d Ripple and Noise (R/N) is shown at Vout=1V. See specs for details.
e The input voltage range must be 0.5V greater than the output voltage.
OKX-T/3-D12 Series
Adjustable 3-Amp SIP Non-Isolated DC/DC Converters
MDC_OKX-T/3-D12 Series.A01 Page 2 of 15
www.murata-ps.com/support