Tradesmig 141 Instruction manual 0349 301 142 080424 Valid for serial no.
DECLARATION OF CONFORMITY Murex Welding Products Ltd. Declare hereby that: Murex Tradesmig 141 Part No. 0349 309 291 Manufactured after 1st May 2005 S conform with the requirements of Council Directive 72/23/EEC, amended by Council Directive 93/68/EEC, relating to electrical equipment designed for use within certain voltage limits. S conform with the requirements of Council Directive 89/336/EEC, amended by Council Directive 93/68/EEC, relating to electromagnetic compatibility.
ENGLISH 1 SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 6 2.1 Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3 TECHNICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 SAFETY Users of welding equipment have the ultimate responsibility for ensuring that anyone who works on or near the equipment observes all the relevant safety precautions. Safety precautions must meet the requirements that apply to this type of welding equipment. The following recommendations should be observed in addition to the standard regulations that apply to the workplace. All work must be carried out by trained personnel well--acquainted with the operation of the welding equipment.
WARNING ARC WELDING AND CUTTING CAN BE INJURIOUS TO YOURSELF AND OTHERS. TAKE PRECAUTIONS WHEN WELDING. ASK FOR YOUR EMPLOYER’S SAFETY PRACTICES WHICH SHOULD BE BASED ON MANUFACTURERS’ HAZARD DATA. ELECTRIC SHOCK -- Can kill S Install and earth the welding unit in accordance with applicable standards. S Do not touch live electrical parts or electrodes with bare skin, wet gloves or wet clothing. S Insulate yourself from earth and the workpiece. S Ensure your working stance is safe.
2 INTRODUCTION Tradesmig 141 are step controlled power sources in a compact design, intended for welding with solid steel, stainless steel or aluminium wire as well as tubular wire with or without shielding gas.The possibility of welding with homogeneous wire/shielding gas and welding with gasless tubular wire is obtained by switching the + and -- connections on the switching terminal by the wire feed unit. ESAB’s accessories for the product can be found on page 15. 2.
Enclosure class The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid objects or water. Equipment marked IP23 is designed for indoor and outdoor use. Application class The symbol indicates that the power source is designed for use in areas with increased electrical hazard. 4 INSTALLATION The installation must be executed by a professional. 4.1 Placing Position the welding power source such way that its cooling air inlets and outlets are not obstructed.
4.
4.4 Mains power supply Check that the unit is connected to the correct mains power supply voltage, and that it is protected by the correct fuse size. A protective earth connection must be made, in accordance with regulations. Rating plate with supply connection data Tradesmig 141 Voltage V 230--240V, 1∼ 50/60Hz Current A at 100% duty cycle 5,1 at 60% duty cycle 7,0 at 20% duty cycle 13,8 Cable area mm2 Fuse slow A 3 x 1.
5.1 Connection and control devices 1 Welding voltage switch OFF + 4 steps (mains ON/OFF) 4 Return cable with clamp, fixed 2 Orange indicating lamp, overheating 5 Knob for wire speed setting 3 Welding gun, fixed 5.2 Functions explanation 5.2.1 Overheating protection If the internal temperature becomes too high, the welding is interrupted and disabled. This state is indicated by lighting of the orange indicating lamp [2] on the front of the machine.
Welding gun Cleaning and replacement of the welding gun’s wear parts should take place at regular intervals in order to achieve trouble--free wire feed. Blow the wire guide clean regularly and clean the contact tip. S 7 FAULT TRACING Try these recommended checks and inspections before sending for an authorised service technican. Actions Type of fault No arc S Check that the mains power supply switch is turned on. S Check that the welding current supply and return cables are correctly connected.
Diagram Tradesmig 141 -- 12 -dT141
Tradesmig 141 Valid for serial no.
Tradesmig 141 Wear components (W. F. Mechanism 0469 475 880) Denomination Ordering no. Notes A Feed roller 0469 517 001 0349 311 443 Ø 0.6--0.8mm Fe, cored wire, CuSi Ø 1.0mm Al B Liner 0700 200 099 0349 311 441 Fe, cored wire, CuSi Al C Contact tip 0700 200 063 0700 200 064 0349 311 442 Ø 0.6mm Fe Ø 0.8mm Fe, cored wire, CuSi Ø 1.0mm Al Item The rollers are marked with wire dimension in mm, some are also marked with inch. Welding with aluminium wires.
Tradesmig 141 Accessories Traction KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . .