Datasheet
Idx. date: check:
DATA SHEET
a 31.08.09 Pan
n
Control input 10.09.10
ri n 13.09.10 Sen
k
MICO 4.6
m
Verlustleistung 01.07.10
ri Ges. 4 channel
l
Überarbeitet 07.04.10
as
k
UL-Sicherungswerte 01.10.09
sb
sheet
j
URZeichenUL2367 25.05.09
ri
Art.-No.: 9000-41034-0100600
2
Idx. Änderun
g
Datu
m
Nam.
3Bl.
a Erstausgabe
15.04.05
DR
Dateiname 9000-41034-0100600_db_e_n
Technische Änderungen vorbehalten / We reserve the right to change this specification Schutzvermerk ISO 16016 beachten / Refer to protection notice ISO 16016
Vom EDV-System heruntergeladene bzw. ausgedruckte Dokumente besitzen informativen Charakter und unterliegen nicht dem Änderungsdienst / Documents downloaded by the EDP system and/or printed out have only an informative character and are not subject to the updating service
turn ON capacity max. 20mF*
accuracy of disconnecting characteristic 0...+20%
internal fuse
6,3A delay fuse for each channel
(UL 248-14, UL File E42088)
* Dependent on: component tolerance, conduit length, used power supply, load current, selected current range
Control output: summation message output pontential-free message output
switching voltage max. 30 VAC/DC
switching current max. 100mA
Additional data: measurements LxWxD 90 x 70 x 80 mm
weight ca. 160g
connection type spring-clamp terminals
environmental temperature -25°C* 0…+55°C
* only with CE
relative humidity 5% - 85% Thawing not permissible
storing temperature -40…+80°C
using category
DC-1, DC-3, DC-5, DC-6, DC-20, DC-21, DC-22, DC-23
fastening snatch able on mounting rail TH 35
according to EN60715
mounting position vertical / unnecessary for multiple modules distance
regulations CE- producer statement
rating isolation voltage 50V, EN 60664-1
degree of pollution 2
classification of over-voltage III
EN 60529 Protective system IP 20
mechanical test EN 60068-2-6 oscillating test
05 - 57,551 Hz; const. amplitude 0,15mm
57,551 - 500 Hz: const. acceleration
EN 60068-2-27 shock test
15g, 11ms duration
EMC test EN 61000-6-2 immunity to interference class A
EN 61000-6-3 interference emission class B
Terminal range profiles:
input max16mm² AWG 06
output max. 4mm² AWG 12 / min.0,5 mm² AWG 20
control input-/ output max. 2,5mm² AWG 12
GND max. 4mm² AWG 12
Function advice:
The module initialization time amounts to generally 250ms. The GND- connection of the equipment is only for supply
of internal electronics. Consumer load must be grounded with separate wires directly to the power supply. The
electrical conductor profile and conductor lengths must be adapted to the adjusted current range! Please pay attention
to the wire capability in relationship of its cross section, ambient temperature, current as well as the used protection.
The in 4 levels settable channel current serves as the wire protection and device protection conform to EN60204-1,
referring to the maximal permissible channel current.
Attention:
- Parallel switching of multiple load branches for increase of power is not permitted.
- Series connection of several MICO module to produce selective switch-off-characteristic is not allowed.
- A generated voltage at output is not allowed to be durably higher than the input voltage.