Specification
Meter/Load Center Combinations
Over/Under Surface Mount, 1 Phase, 3 Wire 120/240 V AC
Main
Amp. Catalog No. of No. of Meter Main 5th
Refer To Dimensions (inches)
Rtg. Number Spaces Circuits Cover Breaker Service Jaw Figure H W D
100 JA110AF
10 20 Ring MP2100 OH N/A 4 19.3 12.1 4.3
100 JA110AS
10 20 Ring MP2100 OH N/A 4 19.3 12.1 4.3
150 JA0408B1150RT 4 8 Ringless MEQ9683R OH/UG EC5J2 1 30.0 13.9 4.9
150 JA0408B1150T 4 8 Ring MEQ9683R OH/UG EC5J2 1 30.0 13.9 4.9
150 JA0816B1150CT 8 16 Ring MEQ9683R OH/UG EC5J2 3 32.0 13.9 4.9
150 JA0816B1150RCT 8 16 Ringless MEQ9683R OH/UG EC5J2 3 32.0 13.9 4.9
200 JA0606L1200
12 6 Ring N/A OH/UG EC5J2 2 27.0 13.9 4.9
200 JA0606L1200R
12 6 Ringless N/A OH/UG EC5J2 2 27.0 13.9 4.9
200 JA0606L1200RA
12 6 Ringless N/A OH/UG EC5J2 2 27.0 13.9 4.9
200 JA0408B1200RT 4 8 Ringless MEQ9685R OH/UG EC5J2 1 30.0 13.9 4.9
200 JA0408B1200T 4 8 Ring MEQ9685R OH/UG EC5J2 1 30.0 13.9 4.9
200 JA0816B1200CT 8 16 Ring MEQ9685R OH/UG EC5J2 3 32.0 13.9 4.9
200 JA0816B1200RCT 8 16 Ringless MEQ9685R OH/UG EC5J2 3 32.0 13.9 4.9
200 JA0816B1200RT 8 16 Ringless MPD2200RH OH EC5J2 5 28.9 12.5 4.9
200 JA0816B1200T 8 16 Ring MPD2200RH OH EC5J2 5 28.9 12.5 4.9
Suitable for use as service entrance equipment when not more than 6
disconnecting means are provided and when not used as a lighting and
appliance panel branch circuit panel board.
10 KAIC rated.
Aluminum enclosure.
Dimensions shown are representative of outside box length, width and
depth and do not include allowance for mounting bumps, endwalls,
covers, hubs or hardware protrusions. Dimensions are subject to change.
Semi-flush mounting.
Not suitable for 5th jaw applications.
Incoming wire range is AL/CU #14-1/0.
Field added.
Lug Wire
Data Range
Incoming #4 AWG - 250 KCMIL
Neutral* #4-14 AWG CU, #4-12 AWG AL
Ground (2) or (3) #14 AWG; (2) #12-10 AWG
Feed Thru Lug 1 AWG - 300 KCMIL
JA0606 Netural Wire Ranges
Small terminal #14 - #6 AWG CU, #12 - #6 AWG AL
Large terminal #14 - 1/0 AWG CU, #12 - 1/0 AWG AL
*Excludes JA0606 devices.
Features
쐍 UL listed
쐍 Overhead and underground feed except where noted
쐍 Field added 5th jaw kits available
쐍 RX hub provisions on top end wall
쐍 HC hub provisions on bottom end wall
쐍 Suitable for use only as service entrance equipment
쐍 22,000 AIC rated, except where noted
쐍 Closure plates included
쐍 Surface mount, except where noted
쐍 Pad locking provisions on all devices
쐍 Contact local utility to confirm meter socket placement
prior to installation
Figure 1
쐍 150 or 200A
쐍 Main breaker
쐍 4 spaces
쐍 Feed thru lugs
Figure 4
쐍 100A
쐍 Main breaker
쐍 10 spaces
쐍 OH feed only
Figure 5
쐍 200A
쐍 Main breaker
쐍 8 spaces
쐍 OH feed only
쐍 Feed thru lugs
Figure 2
쐍 200A
쐍 Main lug
쐍 12 spaces for up
to 6 disconnects
Meter/Load Center Combinations
Side by Side Surface Mount, 1 Phase, 3 Wire 120/240 V AC
Features
쐍 UL listed
쐍 Overhead and underground feed except where noted
쐍 Field added jaw kits available
쐍 RX hub provisions on top end wall
(150 and 200A devices)
쐍 HC hub provisions on bottom end wall
(150 and 200A devices)
쐍 Suitable for use only as service entrance equipment
쐍 Pad locking provisions on all devices
쐍 Contact local utility to confirm meter socket placement
prior to installation
쐍 Closure plate included
Main Incoming
Amp. Catalog No. of No. of Meter Main Bypass 5th
Wire Range Refer To Dimensions (in.)
Rtg. Number Spaces Circuits Cover Breaker Service Type Jaw AL/CU Figure H W D
150 JA0816B1150RTH
8 16 Ringless MPD2150RH OH/UG None EC5J2 #6-250 kcmil 3 21.0 22.8 5.0
150 JA0816B1150TH
8 16 Ring MPD2150RH OH/UG None EC5J2 #6-250 kcmil 3 21.0 22.8 5.0
200 JA0816B1200RTH
8 16 Ringless MPD2200RH OH/UG None EC5J2 #6-250 kcmil 3 21.0 22.8 5.0
200 JA0816B1200TH
8 16 Ring MPD2200RH OH/UG None EC5J2 #6-250 kcmil 3 21.0 22.8 5.0
200 JA2040B1200 20 40 Ring MPD2200RH OH/UG None EC5J2 #6-250 kcmil 1 18.0 22.8 5.0
350 JA0816B1350RLTM
8 16 Ringless MPD2150RH OH/UG Lever S35815-2 (1) 600 kcmil 4 29.0 27.0 6.0
or (2) 250 kcmil
400 JA0408B1400RLTM
4 8 Ringless MPD2200RH OH/UG Lever S35815-2 (1) 600 kcmil 4 29.0 27.0 6.0
or (2) 250 kcmil
400 JA0816B1400RLTM
8 16 Ringless MPD2200RH OH/UG Lever S35815-2 (1) 600 kcmil 4 29.0 27.0 6.0
or (2) 250 kcmil
400 JB230S
20 40 Ringless MPD2200RH UG Lever S35815-2 1 set of 2 studs 2 40.1 30.2 6.2
per lug
Includes #1-300 kcmil Cu/Al feed thru lugs.
If required, order NEMA stud mechanical lugs.
One MPD2200KH installed. Provisions for one additional subfeed MD-TR or
MD-HTR type service disconnect to feed a remote load.
For semi-flush applications use JKF flange kit.
Factory installed 150 Amp breaker with proviisions for second field installed
main breaker up to 200 Amps
Factory installed 200 Amp breaker with provisions for second field instaled
main breaker up to 200 Amps.
Dimensions shown are representative of outside box length, width and
depth and do not include allowance for mounting bumps, endwalls,covers,
hubs or hardware protrusions. Dimensions are subject to change.
Field installed.
Uses HD type hubs.
Lug Wire
Data Range
Incoming in Table
Neutral 4-14 AWG CU, 4-12 AWG AL (Fig. 1 and 3)
Ground (2) or (3) 14 AWG; (2) 12-10 AWG
Feed Thru Lug 1 AWG - 300 KCMIL
Netural Wire Range is #4-300 KCMIL (Fig. 2 and 4)
Small terminal #14 - #6 AWG CU, #12 - #6 AWG AL
Large terminal #14 - 1/0 AWG CU, #12 - 1/0 AWG AL
Hub Trade Catalog
Type Size (inches) Number
RX 1.25 EC38597
RX 1.5 EC38598
RX 2 EC38599
RX 2.5 EC38600
HC 2 ECHC200
HC 2.5 ECHC250
HC 3 ECHC300
HD 2 EC56854
HD 2.5 EC56855
HD 3 EC56856
HD 3.5 EC56857
HD 4 EC56858
Figure 3
쐍 150 or 200A
쐍 8 spaces
쐍 Feed thru lugs
Figure 4
쐍 200A factory installed
main breaker
쐍 Provisions for up to 200A field
installed main breaker
쐍 8 spaces
쐍 Feed thru lugs
Figure 1
쐍 200A
쐍 20 spaces
쐍 Main breaker
Figure 2
쐍 200A factory installed
main breaker
쐍 Provisions for up to 200A field
installed main breaker
쐍 30 spaces
쐍 UG feed only
Hub Accessories
Figure 3
쐍 150 or 200A
쐍 Main breaker
쐍 8 spaces
쐍 Feed thru lugs
NewMurrayFamilyTBrochure2.qxd 5/13/2005 9:04 AM Page 2