Specification

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog
3-13
3
MURRAY
Circuit Breakers
n
Built to order. Allow 8 -10 weeks for delivery.
a
Not UL Listed as SWD Rated.
b
White line neutral (pigtail) must be connected to the
panel neutral for the device to function.
Ground Fault Equipment
Protection (30mA)
b
Type EQF circuit breakers provide protection
of equipment from damaging line-to-ground
fault currents by de-energizing the circuit
for all ungrounded conductors of the faulted
circuit.
Breaker
Type
Amp
Rating
10,000 A IR
Catalog No.
22,000 A IR
Catalog No.
MP-ET/
MP-HET
1-Pole
120V AC
15
20
30
MP115EG
a
MP120EG
a
MP130EG
MP115EGH
n
a
MP120EGHn
a
MP130EGHn
MP-ET/
MP-HET
2-Pole
a
120/240V
AC
15
MP215EG MP215EGH
n
20
MP220EG MP220EGH
n
30
MP230EG MP230EGH
n
40
MP240EG MP240EGH
n
50
MP250EG MP250EGH
n
60
MP260EG
n MP260EGHn
1-Pole GFCI
2-Pole GFCI
1-Pole Branch
Feeder AFCI
AFCI and GFCI Accessories
1-Pole Combination
Type AFCI
2-Pole Combination
Type AFCI
Siemens / Speedfax Previous folio: Murray SS 2/15/11
Arc-Fault Circuit Interrupters (AFCI)
AFCI’s detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit
breakers are unable to detect. The device is intended to mitigate the effects of arcing faults by
functioning to de-energize the circuit when an arc fault is detected
Combination Type AFCI
b
Detects all three possible types of arc faults: line-to-ground, line-to-neutral, and series.
Breaker
Type
Ampere
Rating
10,000 A IR
Catalog Number
22,000 A IR
Catalog Number
65,000 A IR
Catalog Number
MP-AT2/MP-HAT2/
MP-MAT2
1-Pole 120V AC
15
20
MPA115AFC
a
MPA120AFC
a
MPA115AFCHn
a
MPA120AFCHn
a
MPA115AFCHH
MPA120AFCHH
MP-AT2/MP-HAT2
2-Pole 120/240V AC
15
20
MP215AFC
a
MP220AFC
a
MP215AFCHn
a
MP220AFCHn
a
Branch-Feeder AFCI
Detects line-to-ground and line-to-neutral arcs.
MP-AT2/MP-HAT2/
MP-MAT2
1-Pole 120V AC
15
20
MPA115AF
a
MPA120AF
a
MPA115AFHn
a
MPA120AFHn
a
MPA115AFHH
MPA120AFHH
Description Catalog Number
Padlocking Device for 1” & Twin Breakers
ECPLD1
Padlocking Device for 2” & Quad Breakers
ECPLD2
Handle Blocking Device for 1/2” Circuit Breakers
ECBX231M
NEW
Dual Function AFCI/GFCI
The Dual Function Circuit Breaker combines Combination Type AFCI and GFCI, protecting
against both Arc Faults and (5mA) Ground Faults. The device includes the Self Test
feature, making it the first in class in electrical safety for homeowners.
MP-GAT2/MP-HGAT2/
MP-MGAT2
1-Pole 120V AC
15
20
MP115DF
MP120DF
MP115DFH
MP120DFH
MP115DFM
MP120DFM
• UL Listed
• HACR Rated (Except where noted)
Standard 1 inch per pole format
with plug-in design
Ground-Fault Circuit
Interrupters (Class A - 5mA)
b
Ground-fault circuit interrupters (GFCI) provide
Class A ground fault protection. A GFCI is a
device intended for personnel protection
and will de-energize the circuit when a fault
current to ground is 6 milliamperes or more.
Breaker
Type
Amp
Rating
10,000 A IR
Catalog No.
22,000 A IR
Catalog No.
MP-GT/
MP-HGT
1-Pole
120V AC
15
MP115GFA MP115GFAH
n
20
MP120GFA MP120GFAH
n
25
MP125GFA MP125GFAH
n
30
MP130GFA MP130GFAH
n
MP-GT/
MP-HGT
2-Pole
a
120/240V
AC
15
MP215GFA MP215GFAP
n
20
MP220GFA MP220GFAP
n
30
MP230GFA MP230GFAP
n
40
MP240GFA MP240GFAP
n
50
MP250GFA MP250GFAP
n
60
MP260GFA MP260GFAP
n
Ground Fault Interrupters and Protection
Circuit Breakers
Arc-Fault Circuit Interrupters (AFCI)
Product Category RESI