Full Product Manual

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog
3-4
3
MURRAYLoad Centers
a
100-225A only.
b
This information is based on use of 10,000 AIC rated
branch circuit breakers in load center (MP-T, MH-T,
MP-GT, MG). Most series ratings exclude MH-T
above 40 Amp. Consult device wiring diagram for spe-
cific data.
Remote Only
Types MQH & MQL may be mounted internal in 150-225
amp 3
Ø
main breaker load centers.
Dimensions shown are representative of outside box
length, width & depth
1
8”) and do not include allowance
for mounting bumps, endwalls, hubs or hardware protru-
sions. Allow approximately 1
1
4” additional in length and
width dimensions for surface or combination overhang.
Consult factory for specific details if required.
Hub provision only. Closure plate included. Panels
through 225A require HS type hub; panels over 225A
require HV type hub.
Standard package quantity equal to 1.
Copper bus load centers are recommended for those
applications where the environment may be severe
(ie farm and coastal areas).
Rock Solid Load Centers
Main Breaker, 1Ø, 22,000 AIC
a
Load Center Short Circuit Current Rating
Copper Bus
Amps No. of Max. Indoor Type 1
Dimensions
Max. Spaces Circuit Catalog Number Height Width Depth
100 20 40 LC2040B1100CU 24 14
3
8 4
200 20 40 LC2040B1200CU 30 14
3
8 4
200 30 40 LC3040B1200CU 36 14
3
8 4
200 40 40 LC4040B1200CU 39 14
3
8 4
Load Center Short Circuit Current Rating
Load Center Internal or Remote
Short Circuit Load Center Main or Feeder
Current Rating
b
Main Rating Circuit Breaker Type
10,000 AIC Any Any
22,000 AIC 100/125A MP-HT, MQH

150/200/225A MD-H, MQH
b
, MPP-HT
42,000 AIC 100/125A MQL

150/200/225A MQL
b
65,000 AIC 100/125A MP-MT, MPP-MT
150/200/225A MPP-MT
100,000 AIC 100/125A 100A, 300V AC, Class “T” Fuse
100,000 AIC 150/200/225A 200A, 300V AC, Class “T” Fuse
LC2040B1200
Load centers on this page through 200 amp feature a new split neutral with
one bonded and one insulated bar. For service entrance applications, install
bonding strap, and use both bars for neutral and ground conductors. For non
service entrance applications, do not install bonding strap and use insulated
bar for neutral conductors and bonded bar for ground conductors.
Siemens / Speedfax Previous folio: Murray SS 2/14/11
12-42 Circuit, 100-200 Amperes
Amps
Max.
No. of
Spaces
Max.
Circuit
Catalog Number Dimensions
Outdoor Type 3R

Dimensions
Indoor Type 1
Height Width Depth Catalog Number Height Width Depth
100 12 24
LC1224B1100
18 14
3
8 4
LW1224B1100
23 14
1
4 4
1
2
100 16 32
LW1632B1100
23 14
1
4 4
1
2
100 20 40
LC2040B1100
24 14
3
8 4
100 24 40
LC2440B1100
24 14
3
8 4
100 30 40
LC3040B1100
30 14
3
8 4
150 16 32
LC1632B1150
24 14
3
8 4
150 20 40
LC2040B1150
30 14
3
8 4
LW2040B1150
29 14
1
4 4
1
2
150 24 40
LC2440B1150
30 14
3
8 4
150 30 40
LC3040B1150
36 14
3
8 4
200 12 24
LW1224B1200
29 14
1
4 4
1
2
200 16 32
LC1632B1200
30 14
3
8 4
200 20 40
LC2040B1200
30 14
3
8 4
LW2040B1200
29 14
1
4 4
1
2
200 24 40
LC2440B1200
30 14
3
8 4
200 30 40
LC3040B1200
36 14
3
8 4
LW3040B1200
38 14
1
4 4
1
2
200 40 40
LC4040B1200
39 14
3
8 4
LW4040B1200
38 14
1
4 4
1
2
200 30 54
LC3054B1200
36 14
3
8 4
200 40 40
LC4040B1200
39 14
3
8 4
200 40 60
LC4060B1200
40
1
2 15
7
8 5
Product Category RESI
Murray load centers have UL recognized
short circuit current ratings up to 100,000
Amps, when used with appropriate main
or feeder (remote or internal) overcurrent
devices. Load center ratings are shown
below. For load center applications
with residential or commercial metering
equipment, refer to the appropriate
catalog section.
1
Ø
, main breaker load centers are
Underwriter’s Laboratories Listed
for use with 60/75°C conductors and
accept Murray branch circuit breakers
which are also UL Listed for use
with 60/75°C conductors. Type 3R
load centers are furnished with a hub
opening closure plate.