Dimensions Guide

Sectional View
5
1
/
2
"
4
1
/
2
"
SUB-FLOOR
2
1
/
2
"
THRESHOLD
1
"
DRYWALL
1
/
8
"
GAP
5
"
2 x 4
STUD
WALL
SQUARE OPENING
THRESHOLD
A
A
B
B
E.L. Mustee & Sons, Inc. 5431 West 164th Street • Brook Park, OH 44142 • Phone: 216.267.3100 Fax: 216.267.9997
E-mail: info@mustee.com. Web: www.mustee.com • Proudly made in the USA
Notice: Our continuous commitment to product improvement may result in changes to product specifications without notice.
Patents pending. Made and Printed in U.S.A.
DURABASE
®
Fiberglass Shower Floors
Corner, Double Threshold
Design features:
Sturdy, 1-piece molded fiberglass construction — ribbed underbody for
extra strength, slip resistant Starburst® surface
Integral molded drain with seal for connection to 2” Sch. #40 ABS, PVC
or iron DWV sanitary drain pipe. See optional drain seals for 1-1/2” pipe
and 2” copper — removable strainer
Available in White
Semi-gloss surface — resistant to mold and mildew, easy to clean
Designed to be used with Mustees DURAWALL
®
shower walls, ceramic
tile or preformed wall kit
General: Furnish and install as shown on
plans. DURABASE® corner base with double
threshold shower floor model _________ as
manufactured by E.L. Mustee & Sons, Inc.
Floor to be one-piece, molded fiberglass,
made with matched metal molds. Surface to
be slip-resistant Starburst® design that does
not interfere with the flow of water. Size ____” x
____”. Shoulder will be no less than 3” high or
less than 1” wide. Tiling flange will extend not
less than 1” higher than the threshold which
provides an integral molded water barrier.
Threshold will be not less than 4 ½” high.
Molded-in drain and drain seal for installation
of 2” iron DWV (Sch. 40) PVC or ABS sanitary
drain pipe. Removable strainer. Shall meet ANSI
Z 124-2011. Color: White
Code Accepted
International Association of Plumbing and Mechanical Officials® (IAPMO®)
Warnock Hersey® (Canada) Listed – CSA test standards Shower Floor
American National Standards Institute (ANSI) - Specification ANSI Z 124-2011
American Society of Testing and Materials (ASTM) – D.635, E-84 and E-162
CAN/ULC S102-07 Burn and Smoke Test
Specifications
SEE PAGE 2 FOR A LIST OF ACCESSORIES!
Model Nom. Size Color UPC A B
3434DTM 34” x 34” White 6 71031 00098 9 34” 17”
3636DTM 36” x 36” White 6 71031 00144 3 36” 18”