User Manual

Grids
Topographic drum sequencer
Advanced settings
Unplug all CV inputs and hold the TAP (reset) button for
a second to adjust Grids' settings. Refer to the diagram
on the next pages for a list of all available settings. The
3 LEDs indicate the value of the setting being modified.
Hold the TAP (reset) button again for a second when you
are done.
Online manual and help
The full manual can be found online at
mutable-instruments.net/modules/grids/manual
For help and discussions, head to
mutable-instruments.net/forum/
When euclidean sequencer mode is
enabled, the MAP X / Y / CHAOS knobs
have alternate functions, (STEPS 1-3) as
shown in red on the panel – they control
the duration (number of steps) of the
sequence; while the FILL knobs control
the fill rate.
1s
Advanced settings diagram
Sequencer mode
Grids can also work as a plain
euclidean sequencer.
Tap button function
Tap to restart at the beginning
of the sequence
Tap to set the tempo
Grids is yet another
euclidean sequencer
Grids is back to
drumming duties
Trig / Gate output
Outputs are 1 ms triggers
Outputs are gates
Outputs configuration
Grids can output either: three individu-
al accent tracks (one per instrument);
or a global accent track, a clock signal
(received on the clock input or internal,
whichever is used), and a reset trigger
sent at the beginning of the pattern.
ACC 1 / ACC 2 / ACC 3
ACC / CLK / RST
Clock resolution
4ppqn
8ppqn
24ppqn
STEPS 1
STEPS 2
STEPS 3