MC-3 + MC-3.1 AUDIO CLOCK SETTINGS
CLK BASIS
Within this function menu you may select the required basis clock (CLK)
frequency for your studio set-up. This selection serves as the basic setting
for all WCLK output pairs as well as the AES/EBU and S/PDIF outputs. There
are 7 different basis clock rates adjustable by pressing the SELECT key for
different times. The LEDs display the selected clock rate as follows:
The factory default is set at 44.1kHz.
CLK MULTIPLIERS
These multiply functions are separately available for all 4 Word Clock
output pairs as well as for the AES/EBU and S/PDIF outputs. Their
numberings are aligned to the output numbers. Select the prefered output
with the MENU key and choose the needed multiply factor by pressing the
SELECT key accordingly. The factory default is set to x 1.
CLK multipliers 1 4
For every of these Word Clock output pairs are 4 multipliers available:
x 1, x 2, x 4, x 256
The multiply functions »x 1, x 2, x 4« multiply all available basis clocks up to
the highest possible Word Clock rate of 768.0kHz (192.0kHz basis clock x 4).
The function »x 256« multiplies only the basis clocks 44.1kHz and 48.0kHz
to output the so-called Super Clock rates necessary for older digidesign
ProTools™ MX systems. If a different basis clock is selected, the »x 256«
function is not acceccible.
The factory default is set at x 1.
CLK multiplier 5
For the AES/EBU output pair are 3 multiply functions available:
x 1, x 2, x 4
Due to the maximum possible AES/EBU clock frequency of 192.0kHz, the
functions of these multipliers are dependent on the adjusted basis clock.
Example 1
The basis clock runs at 32.0kHz, 44.1kHz or 48.0kHz:
x 1: AES/EBU outputs run at 32.0kHz, 44.1kHz or 48.0kHz
x 2: AES/EBU outputs run at 64.0kHz, 88.2kHz or 96.0kHz
x 4: AES/EBU outputs run at 128.0kHz, 176.4kHz or 192.0kHz
Example 2
The basis clock runs at 88.2kHz or 96.0kHz:
x 1: AES/EBU outputs run at 88.2kHz or 96.0kHz
x 2: AES/EBU outputs run at 176.4kHz or 192.0kHz
x 4: AES/EBU outputs run at 176.4kHz or 192.0kHz
Example 3
The basis clock runs at 176.4kHz or 192.0kHz:
x 1: AES/EBU outputs run at 176.4kHz or 192.0kHz
x 2: AES/EBU outputs run at 176.4kHz or 192.0kHz
x 4: AES/EBU outputs run at 176.4kHz or 192.0kHz
The factory default is set at x 1.
32.0 kHz 44.1 kHz 48.0 kHz 88.2 kHz 96.0 kHz
176.4 kHz 192.0 kHz
CLK MULTIPLIERS
CLK BASIS