User Manual

\\\\\\\\\\\\\
CONTROL ELEMENTS
CONTROL ELEMENTS
CONTROL ELEMENTS
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
88
Manual SDs-01 E 3.2.2003 18:26 Uhr Seite 6
10
For a full list of all Word Clock, AES3 and
S/P-DIF clock rates that can be generated,
please refer to the »Generatable Word Clock
Frequencies« and »Generatable AES3 and
S/P-DIF Frequencies« sections in the APPEN-
DIX chapter.
2 »S/P-DIF OUT 4«
These two S/P-DIF outputs, available as optical and coaxial interfaces, transmit
an optical (»OP«) and unbalanced electrical (»CO«) S/P-DIF digital audio or
blank frame signal in compliance with the IEC 60958 standard. The coaxial
interface impedance is 75 Ω. (RCA connector), the optical interface offers a
Toshiba Toslink
TM
connector, EIAJ standard.
3 »AES3/11 OUT 5«
This AES/EBU output transmits a transformer-balanced electrical digital
audio or blank-frame clock signal in compliance with AES3 –1992 (R1997) or
AES11–1997/2003. Its numbering is aligned to the corresponding functional
menu on the front panel. The output impedance is 110 Ω (XLR connector,
male).
4 »AES3/11 IN«
This AES/EBU input can receive a balanced digital AES3 or AES11 signal in
compliance with AES3 –1992 (R1997) or AES11–1997/2003. The input imped-
ance is 110 Ω (XLR connector, female).
5 »S/P-DIF IN«
These two S/P-DIF inputs, available with optical (»OP«) and coaxial (»CO«)
interfaces, can receive an optical and an unbalanced electrical S/P-DIF digital
audio or blank frame signal in compliance with the IEC 60958 standard. The
coaxial interface impedance is 75 Ω. (RCA connector), the optical interface
offers a Toshiba Toslink
TM
connector, EIAJ standard.
6 »WCLK + 10.0M IN«
This input can receive a Word Clock, a Word Clock x 256 as well as a
10.0MHz reference clock signal. The impedance of the connector is 75 Ω
(BNC connector, female).
7 »MAINS IN«, Power Switch + Mains connector (IEC)
This is the main switch for switching the device on and off. Connect the
supplied IEC power cable to the device‘s mains connector. Make sure that
the power switch is turned off before connecting the device to your power
source finally. Line voltages within the range of 90…260 V with a frequency
of 50 or 60 Hz can be applied. The internal power supply will automatically
make all necessary adjustments.
Read the SAFETY INSTRUCTIONS at the beginning of this manual!