User`s guide

User’s Guide ValueJet 1204
Chapter 4: Handling the printer
82 AP-75740 – Rev 1.2 – 6/07/2011
4.8.1.4 Init.Adj.Print menu
Perform the initial adjust print.
Setup Item Setting Value Description
Feed Length
100 mm to <250 mm> to 500 mm
Change the length (feed length) of the media feed
direction for the initial adjust print.
[Enter] key:
The setting value is determined.
"Printing" is displayed on the operation panel and the
initial adjust print is started.
After printing, the printer enters in the normal status.
[Cancel] key: Cancel the setting value and shift to the
previous hierarchy.
4.8.1.5 Init.Adj.Change menu
Set up Initial Adjust Change.
Setup Item Setting Value Description
Init.
200.0 mm to <250.0 mm> to 300.0
mm
Set up Initial Adjust Change.
[Enter] key: Save the setting and shift to the previous
hierarchy.
[Cancel] key: Cancel the setting and shift to the
previous hierarchy.
4.8.1.6 Confirm Print menu
Perform the Confirm Print.
Setup Item Setting Value Description
Feed Length
100 mm to <250 mm> to 500 mm
Change the length (feed length) of the media feed
direction for the Confirm Print.
[Enter] key:
The setting is determined.
"Printing" is displayed on the operation panel and
initial adjust print is started.
After printing, the printer enters the normal status.
[Enter] key: Save the setting and shift to the previous
hierarchy.
[Cancel] key: Cancel the setting and shift to the
previous hierarchy.
4.8.1.7 Micro Adj. Print menu
Perform the Micro Adjustment Print.
Setup Item Setting
alue Description
Micro Adj. Print
Printing Print the following PF pattern (micro adjustment) with a
focus on the micro adjustment value.
Printing interval: ± 1 pulse
[Cancel] key: Shift to the previous hierarchy.
If the printer is terminated during printing it shifts to the
previous level.
4.8.1.8 Micro Adj.Change menu
Set up the Micro Adjustment Change.
Setup Item Setting Value Description
Micro Adj.Change
–20 pulse to <0 pulse > to 20 pulse Set up the Micro Adjustment Change.
[Enter] key: Save the setting and shift to the previous
hierarchy.
[Cancel] key: Cancel the setting and shift to the
previous hierarchy.