2 INSTALLATION PROCEDURE 
2.1 INSTALLATION ENVIRONMENT 
Be sure to read and understand the safety warnings before handling the printer. 
2.1.1 Environmental conditions for installation 
Floor strength of installation place  More than 2940 Pa (300 kg/m²) 
Power Supply  AC90V – 132V/198V – 264V 
Frequency Range  50/60Hz ± 1Hz 
Power Specifications 
Power Capacity  More than 10 A 
Operative Condition  Temperature: 20°C to 32°C 
Humidity: 40% to 60%, no condensation 
Guaranteed range of 
printing accuracy 
Temperature: 20°C to 30°C 
Humidity: 40% to 60% 
Change rate  Temperature: within 2°C per hour 
Humidity: within 5% per hour 
Environmental conditions 
Archiving environment  Temperature: -20°C to 60°C 
Humidity: 5% to 85% (No Condensation, Ink unfilled) 
 Notes   
•  Concerning temperature and humidity, avoid following locations : 
o  Places where temperature or humidity may rapidly change, even though within the required 
conditions. 
o  Places that receive direct sunlight, increased illumination or direct air, for example from an air 
conditioner. 
•  To keep the temperature and humidity constant, install this product in a location where the air condition 
is adjustable. 