User`s guide

Operation Instructions VJ-1204
13
AP-77170, Rev. 2.0, 2/04/2007
2 INSTALLATION PROCEDURE
2.1 INSTALLATION ENVIRONMENT
Be sure to read and understand the safety warnings before handling the printer.
2.1.1 Environmental conditions for installation
Floor strength of installation place More than 2940 Pa (300 kg/m²)
Power Supply AC90V – 132V/198V – 264V
Frequency Range 50/60Hz ± 1Hz
Power Specifications
Power Capacity More than 10 A
Operative Condition Temperature: 20°C to 32°C
Humidity: 40% to 60%, no condensation
Guaranteed range of
printing accuracy
Temperature: 20°C to 30°C
Humidity: 40% to 60%
Change rate Temperature: within 2°C per hour
Humidity: within 5% per hour
Environmental conditions
Archiving environment Temperature: -20°C to 60°C
Humidity: 5% to 85% (No Condensation, Ink unfilled)
Notes
Concerning temperature and humidity, avoid following locations :
o Places where temperature or humidity may rapidly change, even though within the required
conditions.
o Places that receive direct sunlight, increased illumination or direct air, for example from an air
conditioner.
To keep the temperature and humidity constant, install this product in a location where the air condition
is adjustable.