3/4" flex and multi-conductor for the power and logic circuits is needed for installation. 12 at
most on the multiconductor of wires 18 20 ga stranded.
Instructions for Installation
Customer shall determine which elevator unit they will install the device on, and determine
signal voltages and car top terminal names for the following.
Measure and record:
1. Power (Can be safety circuit or logic common)
2. Inspection
3. Door Open Limit
4. Door Close Limit
5. Interlock (Can be Gate switch if the Interlock isn't available on the car)
Measure and record for optional data:
6. Independent
7. Fire Service
8. Door Zone
In addition, 120 vac power is needed for device power.
Customer submits the following information to Datahoist:
Building Name:
Elevator Name:
Elevator Type (Hydro, traction, etc…):
Elevator Make/Model:
Door Operator Make/Model:
There are 2 terminal blocks, each with it’s own reference terminal. This allows for 2 different
types of circuits to be monitored, from 24 to 120 volts ac or dc. An example pull sheet is
included with this document.
To monitor low voltage circuits (below 60 volts) a jumper is installed on a 2 pin header in front
of the wire terminal.
To install the device, simply fasten to the box to the cartop with screws through the mounting
flanges on the outside of the box.