GENESYS 824 ALPHA INSTALLERS MANUAL Contents INSTALLER PROGRAMMING How to Enter and Move Around Within Installers Program Mode Custom Zone Programming, Location 00-46 Communications Programming, Location 48-56C Entry/Exit Delays, Output Cutoffs, Location 57-58C PGM Output Options, Location 59-59B Misc. Reporting Codes, Location 60-72C Expanders, Keypads and Partitions, Location 73-74 Signal Routing, Location 75-75C System Features, Location 76-79C p. p. p. p. p. p. p. p. p.
To exit a specific Program Location, press the [#] button. This will exit you back to the (PRG.) prompt. When all changes have been completed, depress the [#] button twice to exit out of the Installer Program mode. HOW TO ENTER PROGRAM MODE The Installers PIN is required to access the Installers program. The Installers PIN is Preset from the factory as [9999] and may be changed in Location 78. Care must be taken when changing Installers PIN.
creates a trouble (trbl) condition and will report a trouble code if programmed. In an armed state, an activation will create an alarm condition. 7 - FIRE ZONES are used for devices such as smoke detectors (4 wire), heat sensor, water flow, etc. that need to be active 24 hours. 8 - DAY CIRCUIT is used for devices such as window foil, screens, etc.
Item 58. When this output is turned on as an alarm output, it can not be used for any other function. See Item 58 for cutoff times. Default: NO KEYPAD 1 - 2 - 3 - 4 - is a function that enables or disables the keypad buzzer on entry. This function is only active for Entry - Exit 1 or 2 type zones. The keypads are always silent on alarm violation. Default: YES. 5 - PGM OUTPUT 2 - is an open collector that sinks to ground for the amount of time that is programmed under Item 58.
Value 0 - 9, A - D, Default: FF. The reporting codes in this format must be single digit, therefore you must enter a zero in the first memory location followed by the code number to be transmitted. Example: code 3, program 03. 52 Account Number 1 and 2 (2 Digit Entry) When a reporting function is activated this account number will identify the subscriber to the central station.
57 B Exit Delay #1 (2 Digit Entry) This memory location works in conjunction with a zone type programmed as Entry Exit Zone 1 (see zone type). The value programmed in this memory location will allow a delay on exit when the system is armed in AWAY or STAY modes. Value 00 - 99 seconds, Default: 60 seconds. 56 Local Download PIN (4 Digit Entry) This function works in conjunction with Download Telephone Number (see Memory Location 54 A-G). The telephone number must be programmed for this function to operate.
58 C PGM 2 Cutoff (2 Digit Entry) This output will stay energized for the amount of time programmed in this memory location after an alarm circuit trips and it has been programmed to energize the PGM 2 output, Value 00 - 99 minutes, Default: 0 minutes. 01 - System Armed Status - When this option is selected, this output will be present when the exit time has expired and will remain until the system is disarmed. NOTE: A value of 00 will keep PGM 1 and PGM 2 output energized until a valid PIN is entered.
arming the system. Example: 02 Programmed. Code 2 will be transmitted, the 0 will be dropped as an inconsequential digit. Value 01 - FF, Default: 00 (Disabled). 3 - PGM-1 Keypad Fire - This option allows PGM -1 to energize when the keypad fire is activated .This output will stay active for the period of time programmed in memory location 58B or when a users PIN is entered.
70 B Auxiliary Power Fault Report Code (2 Digit Entry) This code will be transmitted to the central station if the auxiliary power fuse is open. Value 01 - FF, Default: 00 (Disabled). 73 Expander Zone Definition (2 Digit Entry) This location determines the number of Expander Boards (GEX) that are installed.
TOTAL SYSTEM CURRENT (mA) 00 - 100mA 101 - 200mA 201 - 300mA 301 - 400mA 401 - 500mA 501 - 600mA 601 - 700mA 701 - 800mA 801 - 900mA DIGIT TO ENTER IN LOCATION 73C 1 2 Report only to receiver number 2 Report first to receiver number 1, if not successful, attempt to report to receiver number 2 3 Report to receiver number 1 and receiver number 2 4 No Telco reporting for System messages Value 0 - 4 Default: 0 91 92 93 94 95 96 97 98 99 The second digit selects reporting of codes on Long-range radio.
on the Buss for the amount of time programmed in memory location 58A or until a valid PIN is entered in the keypad. Default: NO report+bell = report code(see memory location 71A)+ Panic audible (see below) 3 - Keypad Fire Enabled with this option selected the keypad fire function is enabled ("STAY" and "6"). You may have this function set for silent or audible or both.
2 = Auto.
The zone number you wish to program should be entered as ↑) will lock in your selection two digits (o1-24). Pressing the (↑ and the LCD will change to read: 78 A Duress PIN (4 Digit Entry) This PIN will arm or disarm the system and will transmit the duress report code (see memory location 68B) to the central station. Value 0000 - 9999, Default: BLANK. ENTER ZONE # ZONE ONE NOTE: PIN's (installer, duress, user) cannot be duplicated.
KEYPAD 1 2 3 4 7-11-12 7-9 8-9 7 - 10 SWITCH 1 2 on on on off off on off off a) If programmed as a 24 Hour zone and for trouble report - the audible in the keypad will sound and the communicator will transmit the trouble code to the central station. b) If programmed as a controlled zone (Day/Night) and for Trouble report - the audible in the keypad will sound if the system is disarmed.
16.5VA C , 20VA TR A N S F O RM E R (C O N N E C T TO 24 H R . 1 POW ER SOURCE) 2 S E E N O T E 18 & 19 AC IN C O R R E C T TE RM IN A L B LO C K C O N N E CT IO N M AY D A M A G E E Q U IP M E N T.
zone name have been completed, you must press (INST) to lock your selection into memory. If (INST) is not pressed, the name will revert to the factory default settings. ALPHA PROGRAMMING INSTRUCTION The alpha programming of the control panel is accessed by ↑) 7 & (AWAY). The LCD will entering the installers PIN (↑ change to: ENTER ZONE #. After (INST) is pressed, the LCD will now request another zone number be entered. Repeat the above procedure until all zones have been named.
1st board 2nd board TO INSTALL ADDITIONAL KEYPAD open open open open open closed 1. Set dip switch on the keypad 3. Program memory location 73 SWITCH _2__ _1__ ON ON ON OFF OFF ON OFF OFF KEYPAD 1 2 3 4 4. Program memory location 16 to 46 (custom zone programming for zones 09 to 24) TO INSTALL LONG RANGE RADIO 2. Program memory location 73A in accordance with the number of keypad you installed. 1. Enable Radio output for each zone as necessary in Memory location 00G to 46G.
TO DEFAULT THE 824 CONTROL PANEL The PGM output has a maximum current rating of 20mA. 1. Press [installer pin] + ["] + [7] If you are going to use the PGM outputs for triggering some other control or indicating devices that draw more than 20mA you must use a RELAY MODULE. Your local distributors carry modules such as the ALTRONIX RBSN RELAY MODULES and the ALARM CONTROL CORP. MODEL 8007 RELAY MODULE WITH THE 8012 RELAY which are low current draw relays.
5. Zones set-up time on power up On power up, G-824 ALPHA will ignore all zones for 3 seconds. False alarm reduction features 1. Delay before dial This function enables the subscriber to abort the alarm transmission of burglary zones. If the control panel is disarmed within this prescribed time value. Memory location: 53B Value: 00 - 99 seconds Default: 00 seconds 6. PGM output for armed status PGM’s can be programmed to show armed status for partitioned or non-partitioned status. 7.
within their bedrooms, nor do the required smoke detectors provide reliable early warning protection for those areas separated by a door from the areas protected by the required smoke detectors. For these reasons, it is recommended that the householder consider the use of additional smoke detectors for those areas for increased protection. The additional areas include: basement, bedrooms, dinning room, furnace room, utility room, and hallways not protected by required smoke detectors.
The minimum requirements to form a Listed Grade A Local system includes: Low Battery alarm annunciation (unless dialer is used to transmit a low battery message). CURRENT RATING CHART CONTROL (G-824) KEYPAD (G-KP) FIRE MODULE (G-FM3) EXPANSION BOARD (G-EX) KEYPAD (G-KP ALPHA) BATTERY CALCULATIONS = 100 mA = 24 mA = 50 mA = 29 mA = 40 mA EXAMPLE: 4 HOUR STANDBY PLUS 15 MINUTE BELL RINGING: G-824 Control (with keypad) = Bell 124 mA x 4 hours = .496 AH = 125 mA x 15 minutes = 60 .
DECIMAL TO HEXADECIMAL CONVERSION CHART DEC 000 001 002 003 004 005 006 007 008 009 101 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 034 035 036 037 038 039 HEX 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 DEC 040 041 041 043 044 045 046 047 048 049 050 051 052 053 054 055 056 057 058 059 060 061 062 063 064 065 066 067 068 069 070 071 072 073 074 075 076 077 078 079 HEX 28 29 2A 2B