Vision Security System OWNER MANUAL V-LCD1 Congratulations on your purchase of the OPTEX Vision security system. Vision is an advanced microprocessor based alarm system which provides fire and burglar protection. This manual provides simple operation instructions which will help you enjoy the greatest benefit from your security system with the least difficulty. Please read this manual before operating the system.
SYSTEM REFERENCE GUIDE System Information Central Station Phone Number Central Station Account Number Service Call Arming Your system is programmed for Zone Type Arming Delay Times Exit Delay Time Entry Delay Time Pre-Alarm Delay Time Area Group Arming sec. sec. Mode Arming Exit Delay Time 2 Entry Delay Time 2 sec. sec. sec.
Basic Operation Vision’s ‘Point & Click’ control makes operating your security system quick and easy. For most day to day operations you can simply select the area you wish to secure (A, B, C, or D) and press . If your security system is ‘On’ (armed), entering a valid User PIN turns-off (disarm) the entire system. If the entry delay buzzer is sounding during the disarming process, the button can be pressed before your User PIN to temporarily silence the buzzer.
System Operation The green ‘Ready’ light indicates that all detectors are secure and ready to arm. If the ‘Ready’ light is not on, one or more detectors are activating (open) and are not ready to be armed. Depending on your system’s design, this may or may not prevent your system from arming. Vision’s Zone Indicator lights display which zone(s) have detectors which are in alarm (or open). Check the detector(s) on the zone(s) and arm your system.
User Functions Vision allows system users to control many advanced features. This provides quick service, greater convenience, and lower operating cost. Access these features by pressing and the feature number.
Alarm(s) In Memory [4] Viewing Alarm Memory + 4 Blinking Quad Key(s) while the security system is armed or an “Alarm(s) in Memory” display, indicate that an alarm occured during the most recent arming period. Press + 4 while the system is disarmed to view the first alarm of the arming period. Press 4 again to view each additional alarm of the arming period. A long beep tone indicates there were no additonal alarms. Press to clear the memory or arm and disarm the system.
[6] Bypassing Zones + 6 Detectors (zones) can be manually excluded as you arm your security system (if they are inoperable or if they would conflict with a planned activity). To enter Zone Bypass Mode press + 6 . Press to scroll upwards to the desired zone, or enter the zone number (01, 02, 03, etc...). The display will show the zone number and the status of the selected zone. Zones which are normal, open, or ‘in-trouble’ can be bypassed.
[0] No Exit Delay Arming & Quick Exit 11:33am 08/17/05 Quick Exit + 0 During the exit delay period, enter + 0 to arm the system immediately. This will cancel the remainder of the exit delay. While your system is armed, press + 0 to bypass the entire system for two minutes. You may enter or exit freely until the system automatically returns to its prior armed status at the end of the two minute period. Press to abort this timer and return the system to its armed state.
If you continue, Vision will automatically advance to the address of the next PIN and wait for a four digit code + + two digit autorization level , etc... and automatically return to ‘Home’ of User Programming after the eigth user PIN is programmed. At any time, # can be pressed once to return to ‘Home’ of User Programming; press # a second time to return to system-wide ‘Home’.
[4] Set System Time Clock 4 + Many important Vision features utilize an internal clock to operate. Set, or reset, the clock here. Set hours and minutes (HH:MM) using 24 hour format (1330 = 1:30pm) and press . Then set month and day (MMDD), press , year (YY) and . Complete sequence to set the system clock + 8 + PIN + 4 + + HHMM + + MMDD + + YY + (#, # to exit programming) [5] AM/PM or 24 Hour Clock 5 + If your Vision keypad displays the system time clock, you may select AM/PM or 24 hour display here.
User Activated Alarms Keypad Alarms If equipped, your Vision keypad can be used to report alarms to the monitoring company. Press 2 & 3 for approximately 2 seconds for emergency PANIC alarm ( ). Press 5 & 6 for approximately 2 seconds for emergency FIRE alarm ( ). Press 8 & 9 for approximately 2 seconds for EMERGENCY alarm ( ).