Display manual

8
PAS Ratio setting
To modify the value of PAS ratio can match the different requirements.
For example, the range is 45-55 percent” of 1 level, bottom value can be modified, and
the default is 50 percent. Press MODE to confirm and turn to the next PAS ratio setting.
After all PAS ratio inputted, hold MODE to confirm and return to previous menu, please refer
to
Attached list 3.
PAS Ratio
Interface
Controller Over-Current Cut Setting
CUR means controller over-current cut setting. CUR value can be changed from 7.0A
to 22.0A. Press Up/DOWN to change the value of the current, and hold MODE to confirm
the setting and re turn to previous menu. Default value of controller over-current cut is 15A.
CUR Se tting
Interface
Power Assistant Sensor Setting
The Di rection of Power Assis tant Sensor Setti ng
PAS means power assistant sensor setting. “run-F means forward direction, while
“run-b” means back direction. Press Up/DOWN to select F or b, and press MODE to confirm
and enter to setting mode of PAS sensitivity, the default direction is“run-F”.
Direction of PAS Sensor Setting