DC COMPRESSOR DUAL ZONE FRIDGE-FREEZER MODEL: Truma Cooler C69 DZ US, Truma Cooler C85 DZ US, Truma Cooler C96 DZ US INSTRUCTION MANUAL - 1 -
Congratulations on the purchase of this quality Refrigerator-Freezer. We the manufacturer trust that you will enjoy many years of trouble free use. Please read the instructions carefully before using your Refrigerator - Freezer. This book will provide you with information on how to operate and care for your Refrigerator-Freezer in order to gain the maximum benefit from it.
Warning: 1)This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Press the “Up” or “Down” keys to set the temperature you require. The set temperature will flash for 5 seconds and then automatically change to display the temperature inside the cabinet. To turn off the appliance, remove the plug from socket. Operation with DC12V/DC24V Connect the “DC cable supplied with the appliance to a suitable DC socket outlet .A 120 watt dc socket outlet is recommended. The appliance will automatically identify and apply DC12V or DC24V.
7. Temperature setting button POWER SOCKET PANEL: Front side: The USB socket in the above panel is 5V/3A. it is normally for electrical appliance charge or LED light charge. It is forbidden to charge the appliance which is not within voltage range. When you switch on the Emergency override, the control panel is out of use, compressor will keep on running. It is suggested to use only when the control panel is out of function.
MAIN TECHNICAL PARAMETER Truma Cooler C85 DZ US Truma Cooler C69 DZ US 96L 85L 68.5L 100V-240V~ 100V-240V~ 100V-240V~ VOLTAGE INPUT CURRENT DC POWER AND CURRENT 50~60Hz 50~60Hz 50~60Hz 0.55A at AC240V 0.55A at AC240V 0.53A at AC240V 5A at 5A at 5A at GAS R134a / 98GRAMS R134a / 98GRAMS R134a / 70GRAMS FOAMING LOWEST TEMP. HIGHEST TEMP. C-Pentane C-Pentane C-Pentane -22ºC -22ºC -22ºC +10ºC +10ºC +10ºC 29.8 27.2 MODEL VOLUME Truma Cooler C96 DZ US 12V 2.
TROUBLESHOOTING problem Cause The compressor runs for 1~5 minutes and stops The voltage is not in the normal range The compressor runs but inner liner does not get cold The refrigerant has leaked The inner liner is very cold and the compressor runs continuously.
1 Flash every 4 seconds Low Voltage Try on different power source (vehicle or 240V AC power). If changing power source fixed, then possible issue with the original power source.
direct sunlight, heaters and corrosive gases. The normal operation of the freezer depends on the heat radiation of the condenser. For the initial use, the packing foam must be taken off and at least 150mm space must be left around the freezer. CORRECT DISPOSAL OF THIS PRODUCT: This symbol on the product, or in its packaging, indicates that this product may not be treated as household waste.