SDS
MSDS #
:
2497
Section 8. Exposure controls/personal protection
Use a properly fitted, air-purifying or air-fed respirator complying with an approved
standard if a risk assessment indicates this is necessary. Respirator selection must be
based on known or anticipated exposure levels, the hazards of the product and the safe
working limits of the selected respirator.
Respiratory protection
:
Section 9. Physical and chemical properties
Physical state
Melting point
Vapor pressure
Relative density
Vapor density
Solubility
Liquid [Clear.]
Not available.
Not available.
Not available.
Insoluble in the following materials: cold water.
Petroleum oil
Odor
pH
Pale color.
Color
Evaporation rate
Not available.
Auto-ignition temperature
Flash point
Not available.
Closed cup: 185.6°C (366.1°F) [Pensky-Martens.]
Not available.
Not applicable.
Viscosity
Kinematic (40°C (104°F)): 0.102 cm
2
/s (10.2 cSt)
Not available.
Odor threshold
Partition coefficient: n-
octanol/water
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
Appearance
Boiling point
:
Not available.
Flammability (solid, gas)
:
Flammable in the presence of the following materials or conditions: open flames, sparks
and static discharge and heat.
Lower and upper explosive
(flammable) limits
:
Not available.
Decomposition temperature
:
Not available.
VOC
:
0.5
g/L
VOC Method
:
ASTM E 1868
0.86 g/cm³
Section 10. Stability and reactivity
Hazardous decomposition
products
Conditions to avoid
No specific data.
Under normal conditions of storage and use, hazardous decomposition products should
not be produced.
The product is stable.
Chemical stability
No specific data.
:
:
:
Incompatible materials
:
Possibility of hazardous
reactions
:
Under normal conditions of storage and use, hazardous reactions will not occur.
Reactivity
:
No specific test data related to reactivity available for this product or its ingredients.
Validated on 6/14/2015.