1. Description and functionality 
FLOOD 
DETECTOR 
User Instructions 
Internet user interface 
IT 
ES 
GR PT 
NL  PL 
EN 
Battery protection tab 
Remove the tab to power the detector and trigger the connection to the main unit. 
The detector operates with two AA LR6 alkaline batteries. 
It detects when the batteries are low and alerts the user.  
1 
Detection probe 
When water comes into contact with the electrodes of the detection probe, the detector triggers an alert. 
The probe must be installed as close as possible to the floor, but without touching it. 
We recommend  using the  adhesive square  on one face  of the probe to  secure it firmly to  a flat 
(preferably non-metallic) support surface. 
Recommended position: 2 mm from the floor, with the metal electrodes pointing down. 
Warning: do not place metallic objects in contact with the electrodes. 
2 
3 
Wall-mounting plate 
To operate correctly, the detector must be mounted on its wall-mounting plate. 
When the plate is properly mounted, the detector is clipped onto this mounting. 
Check that it is properly fastened by listening for a "click" when it snaps into place. 
The plate and detector be placed high up, away from any risk of contact with water and electricity. 
When  sorting  your  waste,  please  observe  the  disposal 
regulations in force. Please place waste in the facilities provided 
for that purpose and with all due respect for the environment. 
Note: Replacing the batteries with the wrong type of battery will 
cause a risk of explosion. Dispose of used batteries in 
accordance with instructions. 
3. Battery replacement and wall mounting 
Detector  installation:  use  double-sided 
adhesive strip to secure the plate to the wall, 
or  use  screws  as  follows:  drill  a  hole  in  the 
wall, install the wall plug, and insert the screw 
supplied, leaving a 5-mm gap  between the 
screw head and the wall. Place the slot on the 
head of the screw. The detector and plate 
cannot be flush-mounted. 
TAG Technologies S.A.S. 
Regent Park II – Bât 1 - Rue du Lac 
31 670 Labège – FRANCE 
© TAG Technologies. All rights reserved. 
EMAIL: contact@tag-technologies.com 
HOTLINE: +33 (0)5 61 00 07 11 
121105 – v1.1 
4. Technical characteristics 
 Cat. No. : TA 4006 
 Frequency: Radio 433.92 MHz 
 Range: 150 m in free field 
 'Battery low' supervision  and alert via  message 
from main unit 
 Operating temperature 
 Maximum operating altitude: 2000m 
 Impact protection factor IP 33 
 Batteries: Two AA LR6 alkaline batteries 
 Battery life: 3 years 
 Dimensions: L 100 mm x W 50 mm x D 25 mm 
 Weight: 155 g 
TAG Technologies declares that this product complies with the 
essential  requirements  of  R&TTE  Directive  1999/5/EC. A full 
version  of  the  declaration  of  compliance  is  available  from 
www.myfox.fr/certificats 
2. Connection to the main unit 
 Go into learning mode on your main unit 
 Remove the battery protection tab located behind the detector 
 The main unit emits an audible signal to confirm successful connection 
Batteries: Use a 
screwdriver to open the 
battery hatch at the 
back of the detector, 
and insert the batteries 
in the correct 
orientation (polarity). 