1.5 Intended Use
The Sense MCE IBC is designed for both indoor and outdoor installations. The device can be
installed in ordinary or in hazardous locations. The device is intended for the following user
scenarios (industrial applications):
Digitalization of all IBCs via smart IBC solution
Integrate a full sensorics profile that measures
o fill-level of the IBC
o location (indoor/outdoor)
o movement
o environment (light/air temperature)
o pressure (bulging)
Integrate all data for people and systems to run core business processes
o production and goods issues, inventory count, cleaning, filling/emptying
o alerting and warning
o automatic Electronics / Things Inventory
1.6 Intended Locations
The Sense MCE IBC is intended for operation in the following locations:
Zone 1
o NEC 505 Class I Zone 1 for Gas Groups
o ATEX Group II, Equipment Category 2G
Zone 2
o NEC 500 Class I Division 2
o NEC 505 Class I Zone 2
o ATEX Group II, Equipment Category 3G
WARNING
The classification of Hazardous Zones is outside of the responsibility of
MYNXG. The Zones must be classified by the MYNXG Customer and
their Customers