Operating Instructions

SENSE MCE IBC Operating Instruction
Page 26 of 46 Release Rev. D, 2020-12-15
© MYNXG Product GmbH, 2020. All rights reserved
3.2 Placing the Sense MCE IBC
Rating the cellular radio network and Wi-Fi quality prior placing the Sense MCE IBC is
recommended to avoid bad signal qualities and transmission issues. Appropriate test
software for mobile devices like shown in Figure 6 can be found in the internet.
Figure 6: Wi-Fi Analyzer App
3.3 Installation Instructions
Figure 7 shows the principle of the installation of the Sense MCE IBC and the connected piezo
sensor. The piezo disc is glued directly onto the bottom side of the IBC. For a good functioning
of the measuring method a high quality of the bonding is crucial to ensure, on one hand a good
measurement and on the other hand a long stability and durability of the bonding.
A possible placement of the Sense MCE IBC is on the top side of the IBC, via suitable adhesive
materials. The Sense MCE IBC and the piezo sensor are connected with a cable of suitable
length. The cable is shielded coaxial to reduce potential electromagnetic interferences.
Figure 7: Principle of installation of Sense MCE IBC and connected piezo disc on IBC.