2.7  EMC and ESD concept 
The  MYNXG  Sense MCE IBC  is designed  to be  compliant with  the  EU and  North America 
regulations when installed per MYNXG Sense MCE IBC instructions. 
The following components are shielded by itself: 
▪  The LTE / 3G Modem is shielded, fully type approved and certified. 
▪  The WI-FI module is shielded, fully type approved and certified. 
▪  The Sub-1GHz Short Radio Device (SRD) is shielded and fully certified. 
▪  The device is in line with the EMC Immunity and EMC Emission. 
Furthermore, the PCB board design is done per the following principles: 
▪  On Board EMC and ESD protection components per interface. 
▪  All boards are in line with EMC Immunity Class B EN 61000-6-2. 
▪  All boards are in line with Emission Class A EN 61000-6-3. 
▪  All boards and all components are REACH
1
 and RoHS
2
 compliant with the respective 
EU regulations. 
The Sense MCE IBC industrial is designed for indoor or outdoor applications and should be 
placed with a minimum distance of 50cm for a good radio performance. 
1
 Registration, Evaluation,  Authorization  and  Restriction  of Chemicals  (REACH) is  a European Union regulation 
dating  from  18 December  2006. REACH  addresses the  production  and  use of  chemical substances,  and  their 
potential impacts on both human health and the environment. 
2
 The Restriction of Hazardous Substances Directive 2002/95/EC, (RoHS 1), short for Directive on the restriction 
of the use of certain hazardous substances in electrical and electronic equipment. This directive restricts (with 
exceptions) the use of six hazardous materials in the manufacture of various types of electronic and electrical 
equipment. 