Users Manual
SENSE MCE IBC Operating Instruction 
Page 26 of 46  Release    Rev. D, 2020-12-15 
© MYNXG Product GmbH, 2020. All rights reserved 
3.2  Placing the Sense MCE IBC 
Rating  the  cellular  radio  network  and  Wi-Fi  quality  prior  placing  the  Sense  MCE  IBC  is 
recommended  to  avoid  bad  signal  qualities  and  transmission  issues.  Appropriate  test 
software for mobile devices like shown in Figure 6 can be found in the internet. 
Figure 6: Wi-Fi Analyzer App 
3.3  Installation Instructions 
Figure 7 shows the principle of the installation of the Sense MCE IBC and the connected piezo 
sensor. The piezo disc is glued directly onto the bottom side of the IBC. For a good functioning 
of the measuring method a high quality of the bonding is crucial to ensure, on one hand a good 
measurement and on the other hand a long stability and durability of the bonding. 
A possible placement of the Sense MCE IBC is on the top side of the IBC, via suitable adhesive 
materials. The Sense MCE IBC and the piezo sensor are connected with a cable of suitable 
length. The cable is shielded coaxial to reduce potential electromagnetic interferences. 
Figure 7: Principle of installation of Sense MCE IBC and connected piezo disc on IBC. 