Troubleshooting guide
$ fm_switch -a <switch_name> 
where <switch_name> is the DNS name or IP address for the monitoring line card in the 
specific switch enclosure. 
If you need to remove a switch from the database, run 
  $ fm_switch –d <switch_name> 
If the monitoring line card has not yet been installed in the switch(es), refer to "How do I 
install the monitoring line card in my Myrinet-2000 M3-E* switch?" 
(
http://www.myri.com/cgi-bin/fom?file=200) or "How do I configure the monitoring line card in 
the M3-CLOS-ENCL-* and/or M3-SPINE-ENCL-* switch(es)? (
http://www.myri.com/cgi-
bin/fom?file=374). 
3. Run fm_db2wirelist to look for any missing hosts 
As soon as the FMS database has been created, we recommend running fm_db2wirelist 
to print a list of all connections in the fabric. 
 $ fm_db2wirelist 
fm_db2wirelist reads the database of connections and prints a list of the contents of each 
switch's slots and connections. Reviewing this list is a good way to notice links that have 
lost connectivity. 
  fm_db2wirelist [ -R <fms_run> ] [ -N <db_name> ] 
If a known connected port is missing from the fm_db2wirelist output, refer to the 
following quick-check list: 
•  Is the green LED illuminated on this port? 
•  Is the fiber cable securely attached at both ends? 
•  Is the MX/GM firmware properly installed and running on all nodes (check 
/var/log/messages)? 
•  Is there an fma process running on all hosts in the network? 
•  Does the output of fm_status list all connected hosts, and does it list any alerts? 
•  If the missing connection is a host-to-switch connection, is this host listed in the 
routing table output of mx_info or gm_board_info? 
4. Check the LEDs on each switch port and NIC port 
After the hardware installation and the MX or GM software installation have been 
successfully completed, there will be a green LED illuminated on each switch port (on 
the TFT display) for each connection that is active. If not, check the power supply to the 
switch, and check that the Myrinet cable is securely attached both at the switch end and at 
© 2007 Myricom, Inc. DRAFT 
29