Technical data

06
HI-LINE RC & HI-LINE RC Heater/Cooler
8.0 Electrical Connection
WARNING: This appliance must be earthed. The electrical installation must comply with local or national
wiring regulations.
O O
LN
Brown
Blue
White
Yellow
Motor
Power Board
Control Board
Air Sensor
Water Sensor
O O
Wiring diagram
9.0 Commissioning Procedure
l Fill and vent the system.
l Open both valves fully and check for leaks at pipe
connections.
l Refit the outer case and secure using the 2 fixing screws.
l Switch on electrical supply.
l Check the operation of the unit by following the operating
instructions.
l When installation and commissioning are complete, hand over
instruction manual to end-user.
l This unit is supplied with factory fitted test leads. Remove
these and discard.
l A fused electrical spur with a maximum 3A fuse and a switch,
having 3mm separation on all poles, must be provided in an
easily accessible position adjacent to the unit.
l Electrical cable entry to the unit should be made through the
hole provided at the top left hand side of the unit, using the
cable gland provided.
l Connect live and neutral wires to the power board terminal
connections, and the earth wire to the chassis earth terminal.
23673 HiLine manual UK 27/06/2011 09:12 Page 7