Specifications
MAINS IN
BOILER
ENABLE
ZONE1
ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8
TOUCHPAD NETWORK
ZONE1 / HW
ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8
+ A1 Y
+ A1 B1 Y
- A2 B
- A2 B2 B
+ A1 Y + A1 Y + A1 Y + A1 Y + A1 Y + A1 Y
Y B
+ Y C
- B D- A2 B - A2 B - A2 B - A2 B - A2 B - A2 B
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
Boiler Enable
L SL
FUSE 3
FUSE 1
POWER
WATER
VALVE
PUMP
BOILER
1
2
3
4
5
6
7
8
LOW VOLTAGE
FUSE
HOT WATER
CYLINDER
VALVE
L E N 1 2
OUT IN
HOT WATER
CYLINDER
THERMOSTAT
END SWITCH
L E N 1 2 L E N
END SWITCH
MANIFOLD
VALVE
MANIFOLD
PUMP
ON
OFF
ZONE 7
ON
OFF
ZONE 8
L E N
IN OUT
HEATING
ZONES
230v Mains AC Supply
(from common Boiler /
or System Spur)
BYB2B1A2A1-+ BYA2A1-+ BYA2A1-+
COMBINED HOTWATER
& PROGRAMMABLE ROOM
THERMOSTAT
PROGRAMMABLE ROOM
THERMOSTAT (UFH)
PROGRAMMABLE ROOM
THERMOSTAT
(RADIATOR /TOWELL RAD CIRCUIT)
8 Core Beldon Cable
12v
12v
8 Core Beldon Cable
12v
Volt free Switching
Can be used with
all boiler types
Max 5 amps
240v
240v
240v
240v
+ Y C
- B D
8 Core Beldon Cable
UNDERFLOOR HEATING MANIFOLD
240v to UFH Pump
JG TOUCHPAD
When using Zones 7 or 8 for
controlling radiator circuits
instead of UFH, the switch on the zone
must be in the OFF position to prevent
the UFH pump from operating
This will result in fewer zones being
available for UFH.
The Zone Valve is activated by connecting
the demand wire (normally brown) to the
positive terminal of the appropriate actuator
connection as shown.
Notes
Note 1
See Note 1
See Note 2
Up to 2 Actuators can be connected to the
same terminal. ie max 6 actuators per
zone block.
Note 2
Note 5 - Fuses
Fuse 1
Power Supply (5 Amp)
Fuse 2
Power Supply to LV Transformer
(800ma Time Delay)
Fuse 3
Low Voltage
(800ma Time Delay)
See Note 3
Note 3
Network Connection to Other JGUH1
wiring centres. Boiler Enable to be
wired in parallel.
Note 6 - Network Cable
Two Types are available
a) Cat 5e-ftp
8 Core Network Cable
(Max 30m Run)
b) Beldon 9538 Cable (Recommended)
8 Core Shielded Network Cable
(Max 100m Run)
240v
See Note 4
Optional UFH Manifold Zone Valve
used only to prevent flow of water
to manifold when UFH is off and another
ciruit is in operation.
If Zone Valve is not used a link needs to
be placed between motorised valve
connections marked 1 & L to enable
boiler firing,
Note 4
Optional UFH Zone Valve
Optional DHW Zone Valve
3 Amp Fused Spur
Heat Source
Optional Cylinder Stat
Optional Zone Valve for additonal heating
zone (Towell Rails / Radiators)
See Note 1
JGUH1 Wiring Diagram 12v
Drawn By : MCC/NSDate : 17-09-08 Issue 3
JG Speedfit Ltd., Horton Road West Drayton, Middlesex, UB7 8JL
Tel . 01895 449233
Fax . 01895 420321
www.speedfit.co.uk
ufh@johnguest.co.uk
Technical Helpline 01895 425333
Electrical Installtion Helpline 01254 776343
See Note 3
See Note 7
Note 7
When more than one JGUFH1 is used
in an installation the boiler enable terminal
must be connected to the boiler from each
individual wiring centre.