Specifications
TYPICAL PLATES FROM ABOVE INSTALLATION
22mm Chipboard Floor Deck
(Screwed and Glued to Joist)
Traditional Joists @ 400mm c/c (1 plate / joist spacing)
390mm x 1000mm Heat Spreader Plates
15mm Speedfit Tube
Mineral Wool or Rigid Foam Board Insulation
to building regs.
Plasterboard Ceiling
Floor Covering (Typically Carpet / Vinyl)
Traditional Joists @ 400mm c/c
Pipe fixed to plates from above.
Thin polythene sheet to reduce noise due to expansion
Horton Rd, West Drayton, Middlesex UBL 8JL
Tel. 01895 449233 Fax. 01895 422086
www.speedfit.co.uk
Technical Helpdesk 01895 425333
Issue 2 – FEB 07
SHEET 3
UFH Circuit Return
UFH Circuit Flow
Installation Notes
- Pipe laid in floor at 200mm
centres.
- Uses only 180° bends
which requires min 175mm
bending radius must be observed
to minimise mechanical stress on tube.
- Suitable for joisted floors @ 400mm.
- Heat output is concentrated in part of area.
- Perimeter zones difficult to achieve
if specified.
TYPICAL PIPE LAYOUT FOR TIMBER FLOOR "SINGLE
SERPENTINE / SINGLE MEANDER" PATTERN DETAIL 5