Operating instructions
6
8. Operation
Ensure that the electrical supply is switched on.
8.1. Winter use - for heating
If remote room thermostat is fitted, turn it to a high setting.
Set the fan speed switch to Boost or Low, see Fig. 7.
Set the Summer/Winter switch, see Fig. 7, to the Winter position by pressing to the red top disc.
The fan will now rotate provided hot water is circulating through the heat exchanger at or above 43°C.
If the unit has just been opened to the heating system or the system is not up to working temperature, there will be a
delay before the fan begins to run.
8.2. Temperature control
If a room thermostat is connected to control the Kickspace, its setting should be gradually adjusted to obtain the
required temperature. Use the fan speed switch at Boost or Low as required to increase or decrease the heat output of
the unit.
8.3. Time switch control
It is normal for a heating system to be controlled by a programmer or time switch. Under such control the internal low
temperature thermostat in the Kickspace ensures that the fan will stop after the heating system is switched off and the
water flow stops. It will automatically restart, if left in an operating position, when the heating system is reheated.
8.4. Summer use - for air circulation
If required, the Kickspace can be used in Summer for air circulation without heat. Set the Summer/Winter switch to the
Summer position by pressing to the blue bottom disc.
If a remote room thermostat is fitted, set it to its highest setting.
In this position the fan will run at the selected fan speed until manually reset.
8.5. Remote Control Switch
If a Remote Control Switch is fitted, the fan switch on the unit will be inoperative. Refer to the instructions supplied with the
Remote Control Switch for details.
9. MAINTENANCE
Isolate the electrical supply.
Maintenance should be restricted to occasional removal of dust and lint around the unit. In severe conditions, remove
the top cover and gently remove dust with a soft brush and vacuum cleaner, taking care not to damage the fan or heat
exchanger.
Do not tamper with any electrical parts.
In case of further service requirements, contact your supplier.