370037 - 04 KICKSPACE ® KICKSPACE 800 FAN CONVECTOR O INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS AND TECHNICAL DATA PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE BEGINNING INSTALLATION AFTER INSTALLATION LEAVE THESE INSTRUCTIONS WITH THE USER
LIST OF CONTENTS 1. 2. Application ............................................................... Page 2 Electrical Supply ................................................................. 3 3. 4. Preparation ......................................................................... 3 Water Connections ............................................................. 4 5. 6. Fitting Kickspace ................................................................. 4 Completion ....................................
2. ELECTRICAL SUPPLY WARNING: THIS APPLIANCE MUST BE EARTHED. 2.1 The Kickspace 800 is supplied fitted with a 2 metre 0.75 mm² cord. 2.2 A fused electrical spur with a switch having 3 mm separation on all poles must be provided in an easily accessible position adjacent to the Kickspace, as shown in Fig. 2.2. 2.3 Room Thermostat - If a room thermostat is to be fitted, wire it at this stage. See wiring diagram on page 7. 2.
. WATER CONNECTIONS WATER CONNECTIONS - continued 4.1 Connect flexible pipes to the system flow and return pipes. 4.2 Connect the valve ends of the flexible pipes to the rear of the Kickspace. Note: The direction of flow arrows on the valves are not significant in this application. System pipework Flexible pipes Isolating valves Flexible pipes Fig. 4.1 - Connect flexible pipes to system pipework Fig. 4.2 - Connect the flexible pipes to the Kickspace WATER CONNECTIONS - continued 5.
6. COMPLETION COMPLETION - continued 6.1 Align the grille and secure it to the unit with two screws supplied (use the shorter screws). 6.2 Secure the unit/grille to the plinth with two screws supplied (use the longer screws). It is essential that both sets of screws are used. Front view of unit Front view of unit O O Unit securing screws (long) Grille securing screws (short) Fig. 6.1 - Fit the grille Fig. 6.2 - Secure the unit to the plinth 6.
8. Operation Ensure that the electrical supply is switched on. 8.1. Winter use - for heating If remote room thermostat is fitted, turn it to a high setting. Set the Summer/Winter switch to the winter position by pressing it to the red top disc. Set the fan speed switch to Boost ( ) or Low ( ), see Fig. 7. The fan will now rotate provided hot water is circulating through the heat exchanger at or above 43°C.
11.
USEFUL TELEPHONE NUMBERS Literature Training For copies of the latest Convector range brochure, price lists, full installation instructions and other Potterton Myson product literature, contact the Brochure Hotline on 0345 697509. Fully equipped Training Centres around the country offer a wide range of courses to installers. For details call 01926 430481. Sales Operations After Sales Service A national team of field service engineers and spare parts stockists are available to support the products.