28430 LoLine manual US WEB_Layout 1 28/01/2015 14:51 Page 2 LO-LINE RC & LO-LINE RC HEATER/COOLER FAN CONVECTOR MODELS: 6-4, 9-6, 14-10, 19-15. INSTALLATION, OPERATING, MAINTENANCE & AFTER SALES MANUAL Product Serial Number: Please leave this manual with the end user. Part Number: 1371053 01.01.2015 ISSUE 4 heatingthroughinnovation.
8430 LoLine manual US WEB_Layout 1 28/01/2015 14:51 Page 3 1.0 General Information 03 2.0 Heating System Design 03 3.0 Unit Selection/Sizing 03 4.0 Location 03 5.0 Preparation 04 6.0 Fixing 04 7.0 Water Connections 05 8.0 Electrical Connection 06 9.0 Commissioning Procedure 07 10.0 Technical Data 08 11.0 Operating Instructions 09 12.0 Troubleshooting 10 13.
28430 LoLine manual US WEB_Layout 1 28/01/2015 14:51 Page 4 LO-LINE RC & LO-LINE RC Heater/Cooler 03 l The LO-LINE Heater and Heater/Cooler can be used on low water temperature systems. l The minimum side clearance is 4 inches. l In rooms with ceiling heights above 10ft a ceiling fan or other means of heating stratification should be considered.
28430 LoLine manual US WEB_Layout 1 28/01/2015 14:52 Page 5 04 LO-LINE RC & LO-LINE RC Heater/Cooler 5.0 Preparation Before proceeding with the installation, unpack the carton contents and check against the checklist below: 1. LO-LINE or LO-LINE Heater/Cooler unit. 2. Instruction manual. 3. Fixing kit (rubber mounts and cable gland). 4. Remote control handset. 6.0 Fixing l Using the fixing dimensions (see fig. 1), mark the fixing hole positions on the wall.
28430 LoLine manual US WEB_Layout 1 28/01/2015 14:52 Page 6 LO-LINE RC & LO-LINE RC Heater/Cooler 05 7.0 Water Connections l Connect unit to system flow and return pipes. It is recommended that two 1/2 inch isolating valves are fitted. This will enable isolation of the unit for maintenance activities. Note: To ensure effective venting of the heat exchanger the supply pipe should be connected to the bottom connection of the heat exchanger.
28430 LoLine manual US WEB_Layout 1 28/01/2015 14:52 Page 7 06 LO-LINE RC & LO-LINE RC Heater/Cooler 8.0 Electrical Connection WARNING: This appliance must be grounded. The electrical installation must comply with state or local codes. l This unit is supplied with a factory fitted 3 core cord, 6ft in length with moulded plug.
28430 LoLine manual US WEB_Layout 1 28/01/2015 14:52 Page 8 LO-LINE RC & LO-LINE RC Heater/Cooler 07 9.0 Commissioning Procedure l Fill and vent the system. l Refit outer cover. l Open both valves fully and vent air from the heat exchanger by unscrewing the air bleed valve situated above the valves in the angled top of the chassis. l Switch on electrical supply. l Check for leaks at pipe connections. l Refit the outer case and secure using the 2 fixing screws.
28430 LoLine manual US WEB_Layout 1 28/01/2015 14:52 Page 9 08 LO-LINE RC & LO-LINE RC Heater/Cooler 10.
28430 LoLine manual US WEB_Layout 1 28/01/2015 14:52 Page 10 LO-LINE RC & LO-LINE RC Heater/Cooler 09 11.0 Operating Instructions Description that air circulation can be provided in summer for example, or that heating performance can be controlled manually. This LO-LINE unit is fitted with a control system that provides either automatic or manual control of the unit.
28430 LoLine manual US WEB_Layout 1 28/01/2015 14:52 Page 11 10 LO-LINE RC & LO-LINE RC Heater/Cooler 11.0 Operating Instructions (continued...) Operation Display Manual Power off No Display Manual mode can be used for air circulation without heat or for manual control of the heating function.
28430 LoLine manual US WEB_Layout 1 28/01/2015 14:52 Page 12 LO-LINE RC & LO-LINE RC Heater/Cooler 12.0 Troubleshooting 11 (continued...
28430 LoLine manual US WEB_Layout 1 28/01/2015 14:51 Page 1 RETTIG USA, INC. (MYSON) 45 Krupp Drive, Williston, VT 05495 T: 800-698-9690, F: 802-654-7500, info@myson.com, www.mysoncomfort.com 01.01.2015 ISSUE 4 heatingthroughinnovation.