22369 Slimline RC Manual:Layout 1 10/11/09 16:02 Installation, Operating, Maintenance and After Sales Manual. SLIM-LINE RC heatingthroughinnovation. 01.07.2009 ISSUE 2 Product Serial Number: Please leave this manual with the end user.
2369 Slimline RC Manual:Layout 1 10/11/09 16:02 Page 3 Contents 1.0 General Information 03 2.0 Heating System Design 03 3.0 Unit Selection/Sizing 03 4.0 Location 03 5.0 Preparation 04 6.0 Fixing 04 7.0 Water Connections 05 8.0 Electrical Connection 06 9.0 Commissioning Procedure 07 10.0 Technical Data 08 11.0 Operating Instructions 09 12.0 Troubleshooting 10 13.
22369 Slimline RC Manual:Layout 1 10/11/09 16:02 Page 4 SLIM-LINE RC 03 G The minimum side clearance is 100mm. G The maximum ceiling height is 3m. G Before proceeding with the installation, the heating system design must be considered and the unit correctly sized to meet the heat loss requirements of the room at normal fan speed. G This unit is supplied with an infra red remote control system and can be operated in either automatic or manual mode.
22369 Slimline RC Manual:Layout 1 04 10/11/09 16:02 Page 5 SLIM-LINE RC 5.0 Preparation Before proceeding with the installation, unpack the carton contents and check against the checklist below: 1. SLIM-LINE RC unit. 2. 15mm isolating valves (1 pair). 3. Instruction manual. 4. Warranty card. 5. Fixing kit (rubber mounts and cable gland). 6. Remote control handset. 6.0 Fixing G Using the fixing dimensions (see fig. 1), mark the fixing hole positions on the wall. G Drill and plug the wall for No.
22369 Slimline RC Manual:Layout 1 10/11/09 16:02 Page 6 SLIM-LINE RC 05 7.0 Water Connections G Connect unit to system flow and return pipes using the two 15mm isolating valves (see fig. 2). G Ensure system is flushed in accordance with recognised best practice and a suitable inhibitor is added to the system as necessary. Note: To ensure effective venting of the heat exchanger the flow pipe should be connected to the bottom connection of the heat exchanger.
22369 Slimline RC Manual:Layout 1 06 10/11/09 16:02 Page 7 SLIM-LINE RC 8.0 Electrical Connection WARNING: This appliance must be earthed. The electrical installation must comply with local or national wiring regulations. G This unit is supplied with factory fitted test leads. Remove these and discard. G Connect live and neutral wires to the power board terminal connections, and the earth wire to the chassis earth terminal.
22369 Slimline RC Manual:Layout 1 10/11/09 16:02 Page 8 SLIM-LINE RC 07 9.0 Commissioning Procedure G Fill and vent the system. G Change switch position (see fig. 3). G Open both valves fully and vent air from the heat exchanger by unscrewing the air bleed valve situated above the valves in the angled top of the chassis. G Refit cover. G Check for leaks at pipe connections. G Switch on electrical supply.
22369 Slimline RC Manual:Layout 1 08 10/11/09 16:02 Page 9 SLIM-LINE RC 10.
22369 Slimline RC Manual:Layout 1 10/11/09 16:02 Page 10 SLIM-LINE RC 09 11.0 Operating Instructions Description This SLIM-LINE RC unit is fitted with a control system that provides either automatic or manual control of the unit. In automatic mode the desired temperature set point is selected and the unit will adjust the fan speed according to the difference between the actual room temperature and the set point.
22369 Slimline RC Manual:Layout 1 10 10/11/09 16:02 Page 11 SLIM-LINE RC 11.0 Operating Instructions (continued...) Operation Display Manual Power off No Display Manual mode can be used for air circulation without heat or for manual control of the heating function.
22369 Slimline RC Manual:Layout 1 10/11/09 16:02 Page 12 SLIM-LINE RC 12.0 Troubleshooting 11 (continued...
22369 Slimline RC Manual:Layout 1 10/11/09 16:02 Page 1 MYSON Eastern Avenue, Team Valley, Gateshead, Tyne & Wear NE11 0PG, UK T: 0845 402 3434, F: 0191 491 7568, sales@myson.co.uk, www.myson.co.uk heatingthroughinnovation. After Sales Service: Spare parts and technical help on all Convector products are available from MYSON Service. 01.07.2009 ISSUE 2 MYSON Service, Somerden Road, Hull, East Yorkshire HU9 5PE T: 01482 713927, F: 01482 789056, service.convectors@myson.co.