T6 Radiator Series Installation Guide Revised 1/14 T6-T T6 - CENTRALLY CONNECTED RADIATOR 1
T6 Radiator Series Table of Contents MYSON Before You Begin ..........................................................................3 Bottom Center Connections .......................................................4-5 Side Connections …...................................................................6-7 Optional Piping Arrangements ......................................................8 Wall Bracket Installation ...........................................................
T6 Radiator Series Before You Begin INSPECT FOR DAMAGE NOTE: Inspect for concealed shipping damage. Damage claims MUST be reported within 10 days of receipt. NO EXCEPTIONS. Call 1-800-698-9690. INSPECT FOR COMPLETENESS Unpack the T6 carefully to avoid damage or loss of parts.
T6 Radiator Series Center Connections PIPING CONSIDERATIONS T6 radiators are to be connected to one of the following piping systems: Home Run, Two Pipe Reverse Return, or Monoflo. See page 8 for basic illustrations. A limited number of T6 radiators may be connected in series using “H” Series By-Pass Valves. The circuit must be limited to 2 GPM Maximum. See page 12. Installation Using Center Connections Center connections MUST be used in order for the built-in thermostatic valve to function.
Radiator T6 Series Center Connections (cont) Swapping the right-hand side built-in valve to the left-hand side is no problem at all at any time. Radiators are delivered with protective caps. After removing the protective cap (pos. A) the following thermostat heads can be fitted directly to the built-in valve (pos. B): “RA 2000”, “RAW” by Danfoss, “VK” by Heimeier, “D” by Herz, “thera DA” by MNG and “UNI XD” by Oventrop.
T6 Radiator Series Optional Side Valve Connections Installation Using Side Connections Note: Center connections MUST be used in order for the internal distribution tubing and the built-in thermostatic valve to function. The T6 IVC Radiator is designed to be connected using the bottom connections. If necessary the radiator may be installed using the side tappings although a better alternative is to use Myson’s Select Series Radiators. For more information please contact Myson at 800-698-9690.
T6 Radiator Series Optional Side Valve Installation MYSON Applies to installation using side tappings. Myson products are designed to be installed by professional trades people. Myson instructions are meant to be thorough; however it is assumed that the installer has the appropriate technical knowledge related to building codes, standard trade practices, and proper use of the tools of the trade.
MYSON T6 Radiator Series Optional Piping Arrangements The following drawings are general examples. They are diagrammatic only. Consult a certified heating professional for your specific application.
T6 Radiator Series Solid Wall Bracket Installation ATTENTION: For the correct installation of radiators it is essential that the fixing of the radiator is carried out in such a way that it is suitable for intended use AND predictable misuse. A number of elements need to be taked into consideration including the fixing method ussed to secure the radiator to the wall, the type and condithion of the wall itself, and any additional potential forces or weights, prior to finalizing the installation.
T6 Radiator Series Conventional Wall Installation Using Optional EZ-Brackets) Step 1 Locate studs in wall where the radiator is to be mounted. Step 2 Mount the brackets so the radiator is a minimum of 4 inches off the floor. • Failure to allow 4” minimum clearance below radiator can significantly reduce radiator performance. • Attach brackets firmly to the studs using appropriate hardware making sure the spring loaded connection on brackets is on top.
T6 Radiator Series “H” Diverter Valve Installation MYSON T6 DIVERTER VALVE SYSTEM When using “H” style diverter valves to connect multiple radiators in series, it is necessary to size the downstream radiators based on the lower inlet water temperature at each radiator caused by the mixing of return water. The following is an example of how to properly size each radiator.
T-6 Radiator Series H -Valve Dimensions HV-S Twin Entry By-Pass valve - Straight 2" 22mm BSP 2 3/8" Turn stop flow to radiator turn on both sides.
T6 Radiator Series System Start-Up & Maintenance Failure to flush system of debris and flux may cause premature radiator failure, which can result in leaks and property damage NOT covered under the Myson Warranty. SYSTEM START-UP Step 1 Fill and vent the system. Step 2 Run the system for two (2) hours at full temperature with all radiator valves in the open position. Step 3 Shut off and drain the system while the water is still hot. Step 4 Refill the system. Step 5 Reheat, vent, and balance the system.
T6 Radiator Series Notes MYSON 15
Myson T6 Radiator Installation Manual 6/2012 MYSON INC. 948 Hercules Drive, Suite 5, Colchester, VT 05446 T 800.698.9690 F 802.654.7022 www.mysoninc.