No power to spa:
1. Check proper connection to the pack
2. Check fuse in pack. (30 AMP Slow Blow)
3. Must have very good ground connection - If none call your dealer.
Trips Breaker:
1. Make sure your spa is on a dedicated line.
2. Check breaker to make sure it is wired properly.
3. First take note to how the pump runs before it trips.
Trips instantly:
1. Mis-wired - check electrical wiring.
2. Breaker replacement.
3. Short in Ozone - unhook to check - call your dealer.
4. Short in pumps - unhook to check - call your dealer.
Poor Water Flow:
1. Clean filter.
2. Check if adjustable jets (are all open).
3. May have air lock, prime pump by loosening top pump union.
4. If water diverter valves are present make sure they are all the way open.
5. If gate valves are present, make sure they are all the way open.
6. If none of this works possible line obstruction or impeller loose on pump drive shaft.
No water or air flow to jet:
1. If adjustable jets, probably in off position. (At times the jets can lock into position, may require
some effort.)
2. Pinched line, cutting off flow before reaching spa.
3. Water diverter valve if present may be closed.
Air controls not working:
1. Remove cap on air valve, (with flat head screw driver) and make sure internals are not
broken or improper alignment.
2. If internals are broke, call your dealer.
Jets only have one speed:
1. Programming error, call your dealer.
2. Button not responding, call your dealer.
Heat not working:
1. Make sure the desired temperature is higher than current temperature.
2. Make sure spa is in standard mode. If problem persists contact your dealer or
manufacturer.