FREQUENTLY ASKED QUESTIONS
Q: Why is my spa not heating?
A: You might be in “ECONOMY” or “SLEEP” mode, refer to page 15 for mode options.
The spa MUST be in STANDARD mode for continuous heating. If problem persists,
please contact your dealer or manufacturer.
Q: Why does the system power input fuse (30 A) keep blowing?
A: Chances are the control box is improperly wired or is connected to an insufficient
power source. Check all wires to GFI Breaker, and check all wires from GFI to your
control box. Make sure to replace any blown fuses with a fuse of the exact same type
and rating. You may also have a faulty pump, ozonator, or element. Please contact your
dealer or manufacturer.
Q: Why does the control panel display OH?
A: 1. Overheat protection may occur if the pump is set to operate for extended
periods.
2. In extremely hot weather, check for proper cabinet ventilation.
3. When the hot tub is in a filter cycle make sure pump 1 low-speed is on.
4. Check gate valves make sure that they are open.
5. Check for blockage in the filter cartridge, skimmer basket and pump intake
fittings. If problem persist please call your dealer or manufacturer.
Q: Why isn’t the system maintaining the set temperature of the water?
A: Make sure that the water temperature displayed on the topside panel is at least 1
degree below the heaters set temperature, and set the control to (standard mode).
Q: The system is receiving proper voltage, why doesn’t anything function?
A: 1. Check for blown fuses, burn marks or signs of tampering in the box.
2. Power down the spa, and reset the GFI, if problem persists contact your dealer
or manufacturer.