Instructions for Contractor’s Special™ 2000CS/2001CS Please read before use. Register your product at www.mytee.com/help Model # 2000CS p.2 2001CS p.8 General & Maintenance information p.14 Serial # Form # ADM-CS 3-12 13655 Stowe Dr., Poway, CA.
CONTRACTOR’S SPECIAL™ 2000CS 7 2000CS FRONT 2000CS BACK 8 1 2 3 6 14 13 4 9 12 5 11 1. Waist high controls 2. 2” Male Cuff-Lynx™ 3. Female QD 4. Solution tank 5. Front vent 6. Solution lid 7. Push handle 8. Recovery tank lid 9. 3” casters 10. 8” wheels 11. Rear vent 12. 25’ Power cord 13. Bucket-high drain valve 14. Recovery tank 2000CS ACCESSORIES 10 REPLACING HOSE CUFFS WITH CUFF-LYNX™ 8300 EZ C - 1 2” Wand Twist clock-wise to remove standard cuffs.
CONTRACTOR’S SPECIAL™ 2000CS ATTACH VAC & SOLUTION HOSE TO WAND 2000CS ATTACH HOSES Firmly attach hose and quick disconnect. Make sure quick disconnects snap together firmly. Once attached to unit connect Q.D. to upholstery tool. Always inspect hoses for cracks or fraying. Attach hose cuff to end of wand tube. Attach female QD to male QD located near the wand trigger. 2000CS VACUUM & PUMP 2000CS FILL SOLUTION TANK M UU C VA Lift lid to fill. For best results, fill with warm water (140o F).
CONTRACTOR’S SPECIAL™ 2000CS 2000CS RECOVERY DRAIN 2000CS LOCKING CASTERS When the float shuts off vacuum, empty tank. Pull lever located at the back of the machine to release water. Locking casters help keep the machine remain stationary during use. 2000CS ADDING DEFOAMER 2000CS SYSTEM MAINTAINER Add a defoamer in the recovery tank to reduce foam, prolonging the life of the Contractor’s Special™ vacuum motor .
Order parts at: www.mytee.com/products/product.php?id=2000CS 5 C D E F Part prices are subject to change.
8 to sol tank thru B186 (#48) 11 12 10 13 8 14 9 15 3 7 to sol tank thru B103 (#53) 7 5 16 18 17 20 3 29 6 4 3 22 23 24 25 26 19 8 6 21 20 1 27 30 33 31 28 34 35 2 36 32 5 52 3 47 51 3 49 49 49 46 50 6 37 49 49 49 48 39 45 38 6 40 39 41 to pump "IN" thru B160 (#12) 40 4 57 56 54 61 42 54 53 55 54 55 58 44 43 53 59 60 67 74 63 64 68 to pump "OUT" thru AH108S-25 (#18) 75 62 3 73 65 44 66 2 72 70 69 NAME D Cano
CONTRACTOR’S SPECIAL™ 2000CS WIRING DIAGRAM 7
CONTRACTOR’S SPECIAL™ 2001CS 7 2001CS FRONT 2001CS BACK 8 1 2 3 6 14 13 4 9 12 5 11 1. Waist high controls 2. 2” Male Cuff-Lynx™ 3. Female QD 4. Solution tank 5. Front vent 6. Solution lid 7. Push handle 8. Recovery tank lid 9. 3” casters 10. 8” wheels 11. Rear vent 12. 25’ Power cord 13. Bucket-high drain valve 14. Recovery tank 2001CS ACCESSORIES 10 REPLACING HOSE CUFFS WITH CUFF-LYNX™ 8300 EZ C - 1 2” Wand Twist clock-wise to remove standard cuffs.
CONTRACTOR’S SPECIAL™ 2001CS 2001CS ATTACH HOSES ATTACH VAC & SOLUTION HOSE TO WAND Firmly attach hose and quick disconnect. Make sure quick disconnects snap together firmly. Once attached to unit connect Q.D. to upholstery tool. Always inspect hoses for cracks or fraying. Attach hose cuff to end of wand tube. Attach female QD to male QD located near the wand trigger. 2001CS FILL SOLUTION TANK 2001CS VACUUM, PUMP & HEATER M UU C VA Lift lid to fill. For best results, fill with warm water (140o F).
CONTRACTOR’S SPECIAL™ 2001CS 2001CS RECOVERY DRAIN 2001CS LOCKING CASTERS When the float shuts off vacuum, empty tank. Pull lever located at the back of the machine to release water. Locking casters help keep the machine remain stationary during use. 2001CS ADDING DEFOAMER 2001CS SYSTEM MAINTAINER Add a defoamer in the recovery tank to reduce foam, prolonging the life of the Contractor’s Special™ vacuum motor .
CONTRACTOR’S SPECIAL™ 2001CS PARTS & PRICING 7 8 F E D C B A 6 ITEM NO. PART NO. DESCRIPTION QTY. MSRP 1 2 3 4 5 6 H273 H230 H528 E571 H275 H274 nut, kep, #10-32 zinc screw, 10-32 x 1/2 phil pan bracket, heater mounting, dual heating rod, 600W, 115V 6-32 x 3/16 p-pan internal sem zinc screw, #6 x 3/16, phil pan head, self-tapping 6 2 1 2 8 2 $0.99 ea $0.99 ea $29.99 ea $49.99 ea $0.99 ea $0.
A B C D E F * 7 4 3 8 1 8 2 9 11 10 10 12 # 10 45 28 10 To female q.d.
Cord Input Primary L2 GND Black Inline Conn. Green W hite B lack G reen SW- DPST E515 Inline Conn. Switch Pressure C305 Inline Conn. White Pressure Pump L2 Black Inline Conn. Green W hite B lack C302 Inline Conn. E515 SW- DPST Inline Conn. Vacuum Motor 1 L2 G ND L1 B lack B lue G reen G ND L1 B lack Y ellow Black 2001CS E515 SW- DPST Thermal Switch E571 Green Thermal Switch E571 Heater 2 Heater 1 Mytee Products 13655 Stowe Dr.
GENERAL INFORMATION Dear Customer: Unpacking the Machine Congratulations on the purchase of your new Contractor’s Special™. As you are already aware, the scene of the equipment world is becoming more high tech, and we at Mytee Products Inc. strive to keep you on the cutting edge with superior quality and technology. When the machine is delivered, carefully inspect the shipping carton and the machine for damage.
Setup Maintenance Schedule 1. Open lid of solution tank. Fill solution with water or approved cleaning agent. For best results, fill with warm water (140o). Flammable materials can cause an explosion or fire. Do not use flammable solutions or materials in tank(s). FOR SAFETY: When using machine, follow mixing and handling instructions on chemical containers. ATTENTION: If using powdered cleaning chemicals, mix prior to adding.
Warranty without violating the law. Mytee Products, Inc. endeavors to provide high quality products and product support to its customers and therefore backs up all of its new products purchased from Mytee Products Inc. (Mytee) or any authorized Mytee distributor/service center with this limited warranty. The validity, construction and performance of this warranty policy shall be governed by the laws of the State of California, without respect to conflicts of laws principles.