Instructions for Speedster LTD3, LTD5 & LTD12 ® Please read before use. Register your product at http://www.mytee. com/support/register Model # LTD3 p.2 LTD5 p.9 LTD12 p.16 General & Maintenance information p.
SPEEDSTER® LTD3 SPEEDSTER® LTD3 FRONT SPEEDSTER® LTD3 BACK 1 12 13 2 3 11 4 10 14 23 5 22 9 21 20 6 8 7 1. Switch Plate 2. 2” Male Cuff-Lynx™ Inlet 3. Prime Value 4. Female Quick Disconnect (QD) 5. Front Handle 6. Pressure Regulator 15 19 18 7. Front Fan 8. Side Vents 9. Solution Lid 10. PSI Gauge 11. Recovery Lid 12. Push Handle 17 13. Recovery Tank 14. Solution Tank 15. 4” Locking Casters 16. 10” foam filled semi-pneumatic wheels 17. Hour Meter 18.
SPEEDSTER® LTD3 SPEEDSTER® LTD3 VAC/SOL HOSE CONNECTIONS SPEEDSTER® LTD3 SWITCHES Vac 1 Vac 2 Pump Pump Heater out To use vacuum, turn on Vac 1 and Vac 2. To use pump, turn on Pump. To use pump-out, turn on Pump-Out switch. To use Heater, turn on Heater. Release tool trigger. Wait 8 – 10 minutes for unit to pre-heat. Once heated, re-key upholstery tool until hot water begins flowing. Once hot water is flowing, release trigger and pre-heat an additional 4 – 5 minutes.
SPEEDSTER® LTD3 SPEEDSTER® LTD3 AUTO-FILL CONECTIONS vac stack SPEEDSTER® LTD3 FLOAT SWITCHES Electronic shut-off switches prevents water from getting into the vacuum stack & monitors water level in solution tank. The LTD is equipped with an electronic float switch inside the recovery and solution tank. The recovery float switch is activated by rising water to prevent suction into the vacuum stacks damaging the motors. The solution float switch shuts off the auto-fill once water lever reaches switch.
SPEEDSTER® LTD3 SPEEDSTER® LTD3 SOLUTION TANK DRAIN VALVE SPEEDSTER® LTD3 FILTER MAINTENANCE VACUUM STACK FILTERS (2) PUMP OUT FILTER LOOSEN TIGHTEN REGULATOR BY PASS FILTER INTAKE FILTER The LTD’s five internal filters must be cleaned regularly and are located in the locations listed in the following diagram. Twist the filters to remove them then clean and replace in original locations. If a filter is torn or damaged, replace with a new one.
Order parts at: www.mytee.com/products/product.
8 8 7 148 to heater "IN" thru B207 42 to lg sol tank filter thru B160 68 69 1 38 35 23 to regulator thru AH184 70 5 34 71 32 33 66 32 33 72 33 7 32 67 73 7 31 37 31 74 36 65 44 21 22 23 39 76 75 24 83 to sol tank filter thru B110 17 9 30 20 8 25 110 19 to chemical injector thru H241C 10 26 18 ? 10 6 27 to pump "OUT" thru B136 8 29 148 6 42 to float thru B160 64 10 56 17 9 28 55 58 63 62 16 35 18 15 151 59 61 43 45 44 10
Color diagram at: www.mytee.com/products/product.
SPEEDSTER® LTD5 SPEEDSTER® LTD5 FRONT 12 1 2 SPEEDSTER® LTD5 BACK 13 3 14 4 5 15 6 11 16 7 17 24 8 18 23 9 19 22 10 1. Switch Plate 2. PSI Gauge 3. 2” Male Cuff-Lynx™ Inlet 4. Pressure Regulator 5. Prime Value 6. Female Quick Disconnect 13. Push Handle 14. Recovery Tank 15. Recovery Tank Drain Valve 16. Rear Vacuum Exhaust Optional Muffler Port 17. Service Latches 18. Power cords 7. Front Handle 8. Solution Tank 9. Front Vent 10. 4” Locking Casters 11. Solution Lid 12.
SPEEDSTER® LTD5 SPEEDSTER® LTD5 VAC/SOL HOSE CONNECTIONS SPEEDSTER® LTD5 SWITCHES Vac 1 Vac 2 Pump Pump out Attach female end of a solution hose to a wand or tool and the male end to the LTD’s QD. Then connect a vacuum hose to a wand and the 2” male Cuff-Lynx™ hose port. (If using the optional de-foamer, install the kit onto the vacuum port according to the instructions that come with the de-foamer kit.) To use vacuum, turn on Vac 1 and Vac 2. To use pump, turn on Pump.
SPEEDSTER® LTD5 SPEEDSTER® LTD5 AUTO-FILL CONECTIONS vac stack SPEEDSTER® LTD5 FLOAT SWITCHES Electronic shut-off switches prevents water from getting into the vacuum stack & monitors water level in soultion tank. Using one end of a ½” garden hose, attach it to the mounted connection behind the LTD unit, then attach the other end to the desired faucet connection. Turn on the faucet water and let the auto-fill begin to fill. It will shut off when the water level reaches the LTD’s electronic float switch.
SPEEDSTER® LTD5 SPEEDSTER® LTD5 SOLUTION TANK DRAIN VALVE SPEEDSTER® LTD5 FILTER MAINTENANCE VACUUM STACK FILTERS (2) PUMP OUT FILTER LOOSEN TIGHTEN REGULATOR BY PASS FILTER INTAKE FILTER The LTD’s five internal filters must be cleaned regularly and are located in the locations listed in the following diagram. Twist the filters to remove them then clean and replace in original locations. If a filter is torn or damaged, replace with a new one.
Order parts at: www.mytee.com/products/product.
26 to sol tank filter thru B186 25 4 7 24 32 33 34 33 74 76 3 29 92 23 28 27 28 35 to regulator thru AH184 75 77 78 26 29 31 94 to pressure gauge thru AH117 73 18 7 7 22 30 53 to chemical injector thru H541C 66 70 69 40 68 68 69 67 67 21 8 71 72 6 19 6 26 7 83 18 84 25 18 64 to sol tank float thru B160 65 82 50 59 60 61 81 80 79 20 6 7 7 17 25 16 to pump "IN" thru B160 85 38 36 2 39 37 66 97 87 5 15 14 1 41 40 33 t
G Color diagram at: www.mytee.com/products/product.
SPEEDSTER® LTD12 SPEEDSTER® LTD12 FRONT 12 1 2 SPEEDSTER® LTD12 BACK 13 3 14 4 5 15 6 11 16 7 17 23 8 18 22 9 21 10 1. Switch Plate 2. PSI Gauge 3. 2” Male Cuff-Lynx™ Inlet 4. Pressure Regulator 5. Prime Value 6. Female Quick Disconnect 13. Push Handle 14. Recovery Tank 15. Recovery Tank Drain Valve 16. Rear Vacuum Exhaust Optional Muffler Port 17. Service Latches 18. Power cords 7. Front Handle 8. Solution Tank 9. Front Vent 10. 4” Locking Casters 11. Solution Lid 12.
SPEEDSTER® LTD12 SPEEDSTER® LTD12 VAC/SOL HOSE CONNECTIONS SPEEDSTER® LTD12 SWITCHES Vac 1 Vac 2 Pump Pump out Attach female end of a solution hose to a wand or tool and the male end to the LTD’s QD. Then connect a vacuum hose to a wand and the 2” male Cuff-Lynx™ hose port. (If using the optional de-foamer, install the kit onto the vacuum port according to the instructions that come with the de-foamer kit.) To use vacuum, turn on Vac 1 and Vac 2. To use pump, turn on Pump.
SPEEDSTER® LTD12 SPEEDSTER® LTD12 AUTO-FILL CONECTIONS vac stack SPEEDSTER® LTD12 FLOAT SWITCHES Electronic shut-off switches prevents water from getting into the vacuum stack & monitors water level in soultion tank. Using one end of a ½” garden hose, attach it to the mounted connection behind the LTD unit, then attach the other end to the desired faucet connection. With the auto-pump switch activated, turn on the faucet water and let the auto-fill begin to fill.
SPEEDSTER® LTD12 SPEEDSTER® LTD12 SOLUTION TANK DRAIN VALVE SPEEDSTER® LTD12 FILTER MAINTENANCE VACUUM STACK FILTERS (2) PUMP OUT FILTER LOOSEN TIGHTEN REGULATOR BY PASS FILTER INTAKE FILTER The LTD’s five internal filters must be cleaned regularly and are located in the locations listed in the following diagram. Twist the filters to remove them then clean and replace in original locations. If a filter is torn or damaged, replace with a new one.
Order parts at: www.mytee.com/products/product.
A B C D E F 27 28 58 8 to sol tank filter thru B186 78 8 26 29 30 31 25 32 70 69 77 34 76 71 60 24 24 23 92 to pressure gauge thru AH117 24 92 to regulator thru AH117 68 68 74 40 60 24 18 57 7 7 22 to chemical injector thru H541C 73 7 35 72 75 7 19 79 8 67 20 6 21 58 59 33 62 63 7 80 81 28 6 17 36 65 18 7 66 to sol tank thru B160 18 82 83 6 28 to sol pump "IN" thru B160 64 84 40 16 37 2 38 41 to male garden hose thru
G Color diagram at: www.mytee.com/products/product.
GENERAL INFORMATION Dear Customer: Parts and Service Like any other piece of machinery or technology, the LTDs also requires the proper maintenance and care to keep the product working over extended use. Neglecting your machine, abusing it or not operating it properly can void its warranty and prevent the machine from performing to the quality and standard you’d expect out of the Mytee Products Inc. line.
GENERAL INFORMATION all openings and moving parts. 15. Use extra care when using on stairs. 16. To reduce the risk of fire or electric shock, do not use this machine with a solid-state speed control device. 17. The voltage and frequency indicated on the name plate must correspond to the wall receptacle supply voltage. 18.
GENERAL INFORMATION 5. Remove the solenoid screen and check for any debris or damage to screen. Rinse the screen of any debris or replace if damaged. 6. Replace the ¾” brass plug and screen then you can continue use as normal. the vacuums and cause damage. To maintain these filters: 1. Remove the 7” clear vacuum lid. 2. Reach in and pull out the two black filters located in the top of the vacuum stacks. 3. Clean the filters under a faucet of any debris and check for damage.
GENERAL INFORMATION 7. Using the Philips head screw driver, remove the two Philips head screws and pull the blue face box out. 8. Once the blue switch box is removed, the back end of the vacuum float switch should be visible. 9. Remove the 7” clear vacuum tank lid located on top of the vacuum tank. Use a flashlight to locate the position of the float switch on the front wall inside of the tank. 10.
GENERAL INFORMATION 3. Jets clogged, remove jet and flush clean. 4. Filters clogged, remove filters and rinse clean with water. 5. Heater is blocked; flush out with Mytee’s® System Maintainer. 6. If brass check valve is stuck, replace valve. 7. Check pump wire. May need to reconnect wire. 8. Switch plate may need to be replaced. 9. If pump motor brushes are worn, replace pump. TIES, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF.
GENERAL INFORMATION sions made herein shall be construed to apply to the fullest extent possible without violating the law. The Distributor must follow Mytee Products, Inc. standard RMA procedure: 1. When a repair falls within the Warranty time period for a piece of equipment, the Distributor will fill out a RMA/Warranty claim form. This form will act as a repair order to replace any defective parts.