Operating instructions

18
SPEEDSTER
®
LTD12 AUTO-FILL CONECTIONS
Using one end of a ½” garden hose, attach it to the mounted
connection behind the LTD unit, then attach the other end to
the desired faucet connection. With the auto-pump switch
activated, turn on the faucet water and let the auto-ll begin
to ll. It will shut off when the water level reaches the LTD’s
electronic oat switch.
SPEEDSTER
®
LTD12 RECOVERY DRAIN VALVE
Make sure the Auto-Fill is turned off and then locate and lift the
bucket high drain valve on the rear of the LTD unit to empty
the tanks.
SPEEDSTER
®
LTD12 PUMP-OUT CONNETIONS
Using a separate ½” garden hose, attach one end to the LTD’s
mounted pump-out connection and lay the other end of the hose
in a drainable location. With the pump-out switch activated and
the valve parallel with its pipe, the unit will automatically drain
water from the ll tank while the auto-ll maintains water levels.
Make sure ball valve is open!
SPEEDSTER® LTD12
The LTD is equipped with an electronic oat switch inside the
recovery and solution tank. The recovery oat switch is activated
by rising water to prevent suction into the vacuum stacks damag-
ing the motors. The solution oat switch shuts off the auto-ll once
water lever reaches switch.
Electronic shut-off
switches prevents
water from getting
into the vacuum stack
& monitors water level
in soultion tank.
VAC STACK
SPEEDSTER
®
LTD12
FLOAT SWITCHES