Operating instructions

19
MYTEE
®
SYSTEM MAINTAINER
Weekly ushing of the solution system with Mytee System Main-
tainer helps keep lines clean and prevents chemical build-up,
improving pump life, performance, and pressure.
SPEEDSTER
®
LTD12 SOLUTION TANK
DRAIN VALVE
To remove any remaining water in the solution tank, located on
the back of the unit is a cap, twist and remove cap to
empty tank.
TIGHTEN
LOOSEN
SPEEDSTER® LTD12
SPEEDSTER
®
LTD12
FILTER MAINTENANCE
The LTD’s ve internal lters must be cleaned regularly and are
located in the locations listed in the following diagram. Twist the
lters to remove them then clean and replace in original locations.
If a lter is torn or damaged, replace with a new one.
INTAKE
FILTER
REGULATOR
BY PASS FILTER
PUMP OUT
FILTER
VACUUM
STACK
FILTERS
(2)
SPEEDSTER
®
LTD12 TANK LATCHES
& PUMP HOUR METER
The rear latches can be unlatched from the lower half of the
unit to open it for internal repairs and cleaning. To unlatch, ip
and twist latches. The hour meter activates when the pump
is turned on. This helps monitor usage and when to make oil
changes. Refer to p. 24 for oil maintenance instructions.