Operating instructions
19
MYTEE
®
 SYSTEM MAINTAINER
Weekly ushing of the solution system with Mytee System Main-
tainer helps keep lines clean and prevents chemical build-up, 
improving pump life, performance, and pressure.
SPEEDSTER
®
 LTD12 SOLUTION TANK
DRAIN VALVE
To remove any remaining water in the solution tank, located on 
the back of the unit is a cap, twist and remove cap to
empty tank.
TIGHTEN
LOOSEN
SPEEDSTER® LTD12
SPEEDSTER
®
 LTD12
FILTER MAINTENANCE
The LTD’s ve internal lters must be cleaned regularly and are 
located in the locations listed in the following diagram. Twist the 
lters to remove them then clean and replace in original locations. 
If a lter is torn or damaged, replace with a new one.
INTAKE 
FILTER
REGULATOR 
BY PASS FILTER
PUMP OUT 
FILTER
VACUUM 
STACK 
FILTERS 
(2)
SPEEDSTER
®
 LTD12 TANK LATCHES
& PUMP HOUR METER
The rear latches can be unlatched from the lower half of the 
unit to open it for internal repairs and cleaning. To unlatch, ip 
and twist latches. The hour meter activates when the pump 
is turned on. This helps monitor usage and when to make oil 
changes. Refer to p. 24 for oil maintenance instructions. 