Operating instructions

4
SPEEDSTER
®
LTD3 AUTO-FILL CONECTIONS
Using one end of a ½” garden hose, attach it to the mounted
connection behind the LTD unit, then attach the other end to the
desired faucet connection. Turn on the faucet water and let the
auto-ll begin to ll. It will shut off when the water level reaches
the LTD’s electronic oat switch.
SPEEDSTER
®
LTD3 RECOVERY DRAIN VALVE
Make sure the Auto-Fill is turned off and then locate and lift the
bucket high drain valve on the rear of the LTD unit to empty
the tank.
SPEEDSTER
®
LTD3 PUMP-OUT CONNETIONS
Using a separate ½” garden hose, attach one end to the LTD’s
mounted pump-out connection and lay the other end of the hose
in a drainable location. With the pump-out switch activated and
the valve parallel with its pipe, the unit will automatically drain
water from the ll tank while the auto-ll maintains water levels.
Make sure ball valve is open!
SPEEDSTER® LTD3
The LTD is equipped with an electronic oat switch inside the
recovery and solution tank. The recovery oat switch is activated
by rising water to prevent suction into the vacuum stacks damag-
ing the motors. The solution oat switch shuts off the auto-ll once
water lever reaches switch.
Electronic shut-off
switches prevents
water from getting
into the vacuum stack
& monitors water level
in solution tank.
VAC STACK
SPEEDSTER
®
LTD3
FLOAT SWITCHES