Instructions for M-3, M-5, M-12 & M-16 M-Series™ Please read before use. Register your product at www.mytee.com/help Model # M-3 p. 2 M-5 p. 8 M-12 p.14 M-16 p. 21 General information p. 27 Serial # Form # ADM-MSeries 1-12 13655 Stowe Dr., Poway, Ca.
1
M-3 M-SERIES™ M-3 FRONT M-3 BACK 11 1 2 10 20 12 3 9 19 13 4 14 15 5 8 1. Switch plate 2. 2” Male Cuff-Lynx™ 3. Female quick disconnect (QD) 4. Front handles 5. Prime valve 7 16 6 17 6. Pressure regulator 7. Front cooling fan 8. 4” locking casters 9. Solution tank 10. Solution tank cover 11. Recovery tank lid 12. Push handle 13. Drain valve 14. Auto-fill 15. Auto pump-out M-3 ITEMS INCLUDED 18 16. Rear cooling fan 17. Dual power cords 18. 12” rear wheels 19. Latches (x2) 20.
M-3 M-SERIES™ M-3 VAC/SOL HOSE CONNECTIONS M-3 SWITCHES & PRESSURE GAUGE 1 VAC UMP P 2 VAC TER HEA Switches and Pressure Gauge are located on the plate in front of the machine. The Amber light left of the Pressure Gauge will illuminate when cords are plugged into two separate circuits. To use vacuums, turn on Vac 1 and Vac 2 switches. To use Pump, turn on Pump switch. Heater switch has three positions: Off (middle); 1,000 watts using one heater (left); and 2,000 using two heaters (right).
M-3 M-SERIES™ M-3 AUTO-FILL & FLOAT M-3 PRIME VALVE & PRESSURE REGULATOR PRIME VALVE 1003/1005 HIGHER PSI PRESSURE REGULATOR LOWER PSI After attaching a garden hose to the Auto-fill inlet, water will fill the tank to a predetermined level until stopped by the float. As water is used and the level drops, water will once again enter the tank, and be stopped again by the float when maximum level is reached. With each new job, check to make sure float stops water after the first fill.
Order parts at: http://www.mytee.com/products/product.php?id=M-3 5 A B C D E F B130 H212 B106 17 18 19 8 H202 66 E519 H210 65 H903A H216 64 70 H601 63 69 washer, zinc, 1.625 x .847 x .
6 A B C D E F 94 80 8 48 90 # 53 96 93 to sol tank through B186 95 8 88 65 65 116 25 84 117 53 18 115 94 53 43 25 18 # 20 78 80 92 91 50 50 41 # 87 7 51 114 90 48 81 83 80 78 69 88 80 71 70 to pump "in" 83 17 73 72 to vac tank thru B111 ? # 48 to sol tank thru B105 7 80 82 89 25 74 118 119 65 65 # 25 to sol tank thru B103 53 77 25 85 6 75 121 120 23 66 98 65 6 122 101 # 24 48 83 65 123 97 67 124 112 113 80
7 M3 Wiring Bottom Cord Top Cord PUMP OUT M3 Amber M-3 M-SERIES™ WIRING DIAGRAM
M-5 M-SERIES™ M-5 FRONT M-5 BACK 11 1 2 10 20 12 3 9 19 13 4 14 15 5 8 1. Switch plate 2. 2” Male Cuff-Lynx™ 3. Female quick disconnect (QD) 4. Front handles 5. Prime valve 7 16 6 17 6. Pressure regulator 7. Front cooling fan 8. 4” locking casters 9. Solution tank 10. Solution tank cover 11. Recovery tank lid 12. Push handle 13. Drain valve 14. Auto-fill 15. Auto pump-out M-5 ITEMS INCLUDED 18 16. Rear cooling fan 17. Dual power cords 18. 12” rear wheels 19. Latches (x2) 20.
M-5 M-SERIES™ M-5 VAC/SOL HOSE CONNECTIONS M-5 SWITCHES & PRESSURE GAUGE 1 VAC UT MP O 2 VAC P PUM PU Before turning on switches, connect hoses to the extractor and a wand or tool. Attach a solution hose to the front QD, the other end to the tool. Attach a vacuum hose to the tool, the other to the front Cuff-Lynx™ vacuum hose port. Just twist into place. Switches and Pressure Gauge are located on the plate in front of the machine.
M-5 M-SERIES™ M-5 AUTO-FILL & FLOAT M-5 PRIME VALVE & PRESSURE REGULATOR PRIME VALVE 1003/1005 HIGHER PSI PRESSURE REGULATOR LOWER PSI After attaching a garden hose to the Auto-fill inlet, water will fill the tank to a predetermined level until stopped by the float. As water is used and the level drops, water will once again enter the tank, and be stopped again by the float when maximum level is reached. With each new job, check to make sure float stops water after the first fill.
Order parts at: http://www.mytee.com/products/product.
12 A B C D E F 29 30 31 31 29 32 32 # 75 28 33 34 8 27 57 35 36 11 41 to pump "OUT" thru B186 # 33 to vac tank thru B130 41 8 24 to auto fill thru B115 8 25 6 34 37 31 26 24 38 42 55 11 23 to B644 # 6 24 22 40 # 29 21 # 57 7 to regulator thru B652 to sol tank thru B103 39 59 60 # 41 to sol tank thru B186 7 43 2 20 # 53 to male garden hose, B642 41 41 58 24 25 19 # 24 to B105 # 37 to female QD thru B111 18 12 11 61 56 24 45 3
13 A B C D E F 8 8 115V Top Cord 115V Red Green White 7 Black White Green Bottom Cord 7 White Brown 6 Pump 500psi Vacuum 6 Blue Black Red White 5 Amber Light 5 Red Red Green 4 Green 4 3 White Black Blue 3 Black Black White Black 2 Vacuum Yellow Brown Yellow Pump Out 2 NAME J.Cash DATE 9/10/2010 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF MYTEE PRODUCTS, INC.
M-12 M-12 FRONT M-12 BACK 11 1 2 10 20 12 3 9 19 13 4 14 15 5 8 1. Switch plate 2. 2” Male Cuff-Lynx™ 3. Female quick disconnect (QD) 4. Front handles 5. Prime valve 7 16 6 17 6. Pressure regulator 7. Front cooling fan 8. 4” locking casters 9. Solution tank 10. Solution tank cover 11. Recovery tank lid 12. Push handle 13. Drain valve 14. Auto-fill 15. Auto pump-out M-12 ITEMS INCLUDED 18 16. Rear cooling fan 17. Dual power cords 18. 12” rear wheels 19. Latches (x2) 20.
M-12 M-12 VAC/SOL HOSE CONNECTIONS M-12 SWITCHES & PRESSURE GAUGE 1 VAC UT MP O PU 2 VAC DE P MO PUM CAR PET TILE Switches and Pressure Gauge are located on the plate in front of the machine. The Amber light left of the Pressure Gauge will illuminate when cords are plugged into two separate circuits. To use vacuums, turn on Vac 1 and Vac 2 switches. To use Pump-out, turn on Pump-out switch. To use on carpet, turn the Pump Mode switch to Carpet. To use for Tile, turn the Pump Mode switch to Tile.
M-12 M-12 TILE MODE ON PUMP MODE TILE Press right side of Pump mode button for Tile. The Amber light left of the Pressure Gauge will illuminate when cords are plugged into two separate circuits. In Tile cleaning mode, a 1200 PSI pump will be used. Pump pressure is set using the regulator on the front of the unit. There is no heat in tile mode. It is not possible to run the heater and 1200 PSI pump simultaneously.
M-12 M-12 AUTO-FILL & FLOAT M-12 PRIME VALVE & PRESSURE REGULATOR PRIME VALVE 1003/1005 HIGHER PSI PRESSURE REGULATOR LOWER PSI After attaching a garden hose to the Auto-fill inlet, water will fill the tank to a predetermined level until stopped by the float. As water is used and the level drops, water will once again enter the tank, and be stopped again by the float when maximum level is reached. With each new job, check to make sure float stops water after the first fill.
Order parts at: http://www.mytee.com/products/product.
A B C D E F # 97 to auto fill thru B115 33 8 32 4 34 50 39 49 51 39 48 38 8 45 # 59 to male garden hose thru B642 31 35 42 46 41 36 37 40 15 47 52 53 25 24 26 30 9 44 23 28 2 21 29 7 # 43 to heater "IN" thru B207 # 2 20 32 7 18 19 # 21 17 to QD (lower) thru B107 # 1 to 220 psi pump "OUT" thru B108 to heater "OUT" thru AH184 22 43 27 22 56 55 54 7 16 1 15 68 33 2 14 8 35 2 9 64 32 32 13 12 61 62 6 8 7 # 72 3 to sol tan
20 A Black White B White Green 115v Pump 200 Pump 1200 Pump Out Green Green Top Cord Black White 115v Bottom Cord B White Black Black Motor 2 C White Motor 1 Blue Red Green C Yellow H2 H1 1000W 4 3 2 1 Mytee Products, Inc.
M-16 M-16 FRONT M-16 BACK 11 1 2 10 20 12 3 9 19 13 4 14 15 5 8 1. Switch plate 2. 2” Male Cuff-Lynx™ 3. Female quick disconnect (QD) 4. Front handles 5. Prime valve 7 16 6 17 6. Pressure regulator 7. Front cooling fan 8. 4” locking casters 9. Solution tank 10. Solution tank cover 11. Recovery tank lid 12. Push handle 13. Drain valve 14. Auto-fill 15. Auto pump-out M-16 ITEMS INCLUDED 18 16. Rear cooling fan 17. Dual power cords 18. 12” rear wheels 19. Latches (x2) 20.
M-16 M-16 VAC/SOL HOSE CONNECTIONS M-16 SWITCHES & PRESSURE GAUGE 1 VAC UT MP O 2 VAC P PUM PU Before turning on switches, connect hoses to the extractor and a wand or tool. Attach a solution hose to the front QD, the other end to the tool. Attach a vacuum hose to the tool, the other to the front Cuff-Lynx™ vacuum hose port. Just twist into place. Switches and Pressure Gauge are located on the plate in front of the machine.
M-16 M-16 AUTO-FILL & FLOAT M-16 PRIME VALVE & PRESSURE REGULATOR PRIME VALVE 1003/1005 HIGHER PSI PRESSURE REGULATOR LOWER PSI After attaching a garden hose to the Auto-fill inlet, water will fill the tank to a predetermined level until stopped by the float. As water is used and the level drops, water will once again enter the tank, and be stopped again by the float when maximum level is reached. With each new job, check to make sure float stops water after the first fill.
Order parts at: http://www.mytee.com/products/product.
25 A B C D E F # 67 To auto fill thru B186 8 8 40 41 42 31 37 38 43 10 # 21 To B642 45 3 7 4 2 # 53 1 To regulator thru B107 24 11 35 36 # 98 To vac tank thru B236 44 7 51 50 48 5 34 6 # 7 8 53 6 7 # 85 # 53 33 55 32 52 To q.
8 8 26 38.27 115V Top Cord 115V Red 7 Green White Black White Green Bottom Cord 7 White Blue 6 Vacuum Pump 1200psi 6 Brown Black Red White 5 Amber Light 5 Red Red Green 4 Green 4 3 NAME J.Cash 9/10/2010 DATE THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF MYTEE PRODUCTS, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF MYTEE PRODUCTS, INC. IS PROHIBITED.
General information Dear Customer: Unpacking the Machine Keep in mind that the M-Series™ Extractor is a machine, so neglect or abuse will cause unnecessary damage and void the warranty. However with simple maintenance the M-Series™ will give quality performance for many years to come. Caution and Warnings Congratulations on the purchase of your new M-Series™ Extractor. As you are already aware, the scene of the equipment world is becoming more high tech, and we at Mytee Products Inc.
General Information 5. Attach one end of the vacuum hose from a wand or other attachment to the front Cuff-Lynx™ vacuum hose port. 6. Plug in power cords. • M-3 – Plug the top power cord into a 20A grounded wall outlet to turn on Vac 1, Pump and Heater 1. Using a second 20A grounded wall outlet on a separate circuit, plug in the bottom cord to turn on Vac 2, Pump-out and Heater 2. The amber light indicator on the switch plate will illuminate brightly when cords are plugged into two separate circuits.
General information then the remaining provisions and portions shall remain valid and enforceable. If any provision or portion of this limited warranty policy is found to be limited by law, then that provision or portion shall be construed to make it effective within the bounds of law.